| SUPP |
SUPPLEMENTARY FEATURES |
THE LAV-C2 APU EXHAUST SYSTEM SHALL DISPERSE HOT GASSES AWAY FROM THE VEHICLE/MINIMIZE THERMAL SIGNATURE;APU SHAKLL USE BULKHEAD TYPE,FUEL INE FITTINGS ORIENTED PARRALLET TO THE BASE AND FACING THE REAR OF THE APU ENCLOSURE;STANDARD 3/8INCH SAE J514 37DEG FLARE;APU MODIFIED TO ALLOW MANUAL START (HAND CRANK)IN CASES WHERE BATTERIES FAIL OR ARE MISSING AND IF REMOVAL OF FUEL SUPPLY SOLENOID OCCURS |
| BDWW |
WATTAGE RATING |
4000.000 WATTS |
| ARAG |
CURRENT RATING |
120.000 AMPERES |
| MARK |
SPECIAL MARKINGS |
PANDA AGT4000 LAV |
| AGAV |
END ITEM IDENTIFICATION |
LAV-C2A2;2355-01-539-3589 |
| TEXT |
GENERAL CHARACTERISTICS ITEM DESCRIPTION |
AUXILLIARY POWER UNIT (APU) GENERATOR,ASSOCIATED RADIATOR AND CONTROL BOX PROVIDED FOR INTEGRATION INTO THE LAV-C2 VEHICLE |
| HUES |
COLOR |
GREEN |
| MATT |
MATERIAL |
STEEL CORROSION RESISTING |
| CSBH |
VOLTAGE IN VOLTS AND CURRENT TYPE |
28.0 DC |
| FEAT |
SPECIAL FEATURES |
COLOR CHIP NO.34094 OLIVE DRAB,LUSTERLESS IAW FED-STD-595;APU SHALL BE CONTROLLABLE (START AND STOP) FROM THE CONTROLLER AND PROVIDE STATUS INDIATORS TO THE CREW WHILE WITHIN THE VEHICLE;APU RUNS ON THE SAME FULES AVAILABLE TO THE LAV-C2 IAW A-A-52557;NOISE LEVEL AT 1/2 LOAD SHALL NOT EXCEED 66 DB(A) AT 3 METERS |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
AUXILLIARY POWER UNIT (APU), LAV |
| SPCL |
SPECIAL TEST FEATURES |
APU MEETS MIL-STD-461E FOR EMI;ENGINE,FUEL PUMP,WATER PUMP AND EXHAUST FAN MUST BE GROUNDED TO HULL OF VEHICLE |