| FREQ |
FREQUENCY IN HERTZ |
60.0 |
| AHZF |
CENTRIFUGAL PUMP IMPELLER QUANTITY |
1 |
| AHZV |
SUBMERSIBILITY (NON-CORE) |
NONSUBMERSIBLE |
| ADZC |
ENVIRONMENTAL PROTECTION |
DRIPPROOF |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| AAXS |
PRIME MOVER COOLING MEDIUM |
AIR |
| AAYU |
INTAKE CONNECTION TYPE |
THREADED INTERNAL |
| AGAV |
END ITEM IDENTIFICATION |
USED ON 82 FT COAST GUARD VESSELS |
| AHYX |
TOTAL HEAD |
28.000 FEET |
| ELEC |
VOLTAGE IN VOLTS |
230.0 AND 460.0 |
| AENC |
PUMP QUANTITY |
1 |
| AHYZ |
OPERATING SPEED AT RATED CAPACITY |
3450.0 REVOLUTIONS PER MINUTE |
| ASWT |
INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR |
1.250-11-1/2 NPT |
| AMPS |
CURRENT RATING IN AMPS |
40.0 AND 20.0 |
| AKDJ |
PRIME MOVER TYPE |
ELECTRIC MOTOR |
| AHZG |
CENTRIFUGAL PUMP IMPELLER SUCTION TYPE |
SINGLE |
| FAAZ |
PHASE |
THREE |
| AAYW |
DISCHARGE CONNECTION TYPE |
THREADED INTERNAL |
| AHZA |
PUMPING ELEMENT OPERATING POSITION |
HORIZONTAL |
| AHYW |
DISCHARGE PRESSURE |
12.1 POUNDS PER SQUARE INCH GAGE |
| AHYY |
SUCTION LIFT |
25.000 FEET |
| ASAZ |
DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR |
1.000-11-1/2 NPT |
| AFJK |
CUBIC MEASURE |
2.0058 CUBIC FEET |
| AAYT |
INTAKE CONNECTION QUANTITY |
1 |
| AAXH |
PRIME MOVER QUANTITY |
1 |
| AAYD |
STAGE QUANTITY |
1 |
| AHYV |
MAXIMUM DISCHARGE FLOW RATE |
33.0 GALLONS PER MINUTE |
| ACKL |
MEDIA FOR WHICH DESIGNED |
WATER, FRESH |
| AAYV |
DISCHARGE CONNECTION QUANTITY |
1 |
| AAXX |
MOUNTING TYPE |
BASE |
| AENK |
COOLING METHOD |
BLOWER COOLED |
| CSYL |
PRIME MOVER POWER RATING |
0.5 HORSEPOWER |
| ACDC |
CURRENT TYPE |
AC |
| AHZE |
CENTRIFUGAL PUMP DESIGN |
RADIAL FLOW |