4520-01-176-1268 ( 17713-12KW , 17722 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 4520-01-176-1268 | 4520 | 011761268 | HEATER,WATER,ELECTRIC | 0718 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AMHR | HEATING CAPACITY PER HOUR | 60.0 GALLONS |
| AMLR | WATER OUTLET CONNECTION QUANTITY | 1 |
| AHGR | INSULATED FEATURE | INCLUDED |
| AMLL | WATER INLET CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 0.500-14 NPT |
| AEEA | SWITCH TYPE | SINGLE THROW |
| ALHG | ATTACHMENT DEVICE | NOT INCLUDED |
| AKYN | FURNISHED ITEMS AND QUANTITY | SAFETY VALVE 1; FITTINGS 6; THERMOMETER 1 |
| AMHX | TEMP RISE PER HOUR | 80.0 DEG FAHRENHEIT |
| AMKA | TANK CAPACITY | 25.0 GALLONS |
| FAAZ | PHASE | THREE |
| AAJQ | INSIDE SURFACE TREATMENT | TINNED |
| AMLM | WATER OUTLET CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 0.500-14 NPT |
| MATL | MATERIAL | COPPER-SILICON ALLOY AND STEEL, CORROSION RESISTING |
| AMJX | THERMOSTATIC SWITCH | NOT INCLUDED |
| ADAV | OVERALL DIAMETER | 17.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 49.000 INCHES NOMINAL |
| AMLQ | WATER INLET CONNECTION QUANTITY | 1 |
| ACDC | CURRENT TYPE | AC |
| AMRK | HEATING ELEMENT WATTAGE RATING | 12000.000 LOWER |
| AAJJ | MAXIMUM OPERATING PRESSURE | 70.0 POUNDS PER SQUARE INCH |
| ELEC | VOLTAGE IN VOLTS | 440.0 |
| ABAL | HEATING ELEMENT TYPE | TRIPLE |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 17713-12KW | 19857 | A | 1 | C | AC | 6 | ZZ |
| 17722 | 19857 | A | 2 | 3 | A | AX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 17713-12KW | 19857 | ELECTRIC HEATER COMPANY THE | A | A |
| 17722 | 19857 | ELECTRIC HEATER COMPANY THE | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 04/07/1 | N | 8516100040 | 0718 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DS | I | ||||
| DN | 9B----- | N |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | J | 1 | EA | 0 | U | D | ||
| DN | SMS | J | 1 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 026520 | Z | 12648 | W | 658 | Z | 9 | A | H | Z | HEATERS WATER |