| FREQ |
FREQUENCY IN HERTZ |
60.0 |
| AZQH |
MAXIMUM WATTAGE RATING IN WATTS |
10600.0 SINGLE VOLTAGE OR 14100.0 SINGLE VOLTAGE |
| AALX |
MOUNTING METHOD STYLE |
FLANGE TYPE MOUNTING FACILITY |
| FEAT |
SPECIAL FEATURES |
MODIFIED TERMINAL HOUSING IS WELDED TO ELEMENT MOUNTING FLANGE AND HAS AN INTERNALLY THREADED 0.75NPT CONDUIT ENTRANCE AND A 7.75" DIA 8 HOLE ROUND FLANGE AT ITS END |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
MODIFIED HEATER ELEMENT ASSENBLY |
| ABJS |
ELEMENT CONNECTION STYLE |
STUD TYPE |
| AARA |
TERMINAL QUANTITY |
12 |
| ABNR |
HEAT QUANTITY |
1 |
| ABJA |
ELEMENT RADIATION SPECTRUM |
NONINFRARED |
| ABNT |
CONDUIT OPENING SIZE |
0.750 INCHES NOMINAL |
| ABKK |
FLANGE DIAMETER |
9.000 INCHES NOMINAL |
| AAQL |
BODY STYLE |
FLANGE, TYPE |
| FAAZ |
PHASE |
THREE SINGLE VOLTAGE |
| MATT |
MATERIAL |
NICKEL ALLOY SHEATH |
| ABKF |
TERMINAL BOX ENVIRONMENTAL PROTECTION |
EXPLOSION RESISTANT AND MOISTURE RESISTANT |
| CSBH |
VOLTAGE IN VOLTS AND CURRENT TYPE |
220.0 AC SINGLE VOLTAGE OR 440.0 AC SINGLE VOLTAGE |
| ABRY |
LENGTH |
33.000 INCHES NOMINAL |
| ABKT |
HOLE OR SLOT QUANTITY |
8 |
| BHHK |
ELEMENT QUANTITY |
6 |
| ABHP |
OVERALL LENGTH |
39.430 INCHES NOMINAL |
| ABKU |
FLANGE THICKNESS |
0.930 INCHES NOMINAL |
| ABJT |
TERMINAL LENGTH |
2.500 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
3655-01-395-9203; WEAPONS SYSTEM 46, JOINT SURVEILLANCE SYS (JSS)/REGION OPS CONTROL CENTER (ROCC) |