| CRXX |
MEASURING METHOD AND LENGTH |
216.000 INCHES NOMINAL EXCLUDING END FITTINGS |
| CRWL |
INSIDE SURFACE CONDITION |
SMOOTH |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
ROUND |
| CQGH |
FIRST END FITTING/COMPONENT AND MATERIAL |
COMPLETE FITTING BRASS, QQ-B-626, ALLOY 360, 1/2H |
| ABJH |
TEMP RATING |
-65.0 DEG FAHRENHEIT SINGLE RESPONSE AND 250.0 DEG FAHRENHEIT SINGLE RESPONSE |
| CQCS |
LAYER COMPOSITION AND LOCATION |
1ST LAYER BRAIDED COTTON CORD ERR-100 |
| THSD |
THREAD SERIES DESIGNATOR |
NPTF 2ND END |
| CRDW |
HYDROSTATIC TEST PRESSURE |
850.0 POUNDS PER SQUARE INCH |
| CQGM |
MAXIMUM OPERATING PRESSURE |
425.0 POUNDS PER SQUARE INCH |
| ADLG |
FIRST END FITTING SPEC/STD DATA |
MS39158-3 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
| AARX |
INSIDE DIAMETER |
0.188 INCHES NOMINAL |
| ADLF |
HOSE OR TUBING SPEC/STD DATA |
MIL-H-13444,TYPE 1 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |
| AWLS |
CONNECTION TYPE |
THREADED INTERNAL PIPE 2ND END |
| CQCS |
LAYER COMPOSITION AND LOCATION |
OUTER LAYER MOLDED RUBBER, SYNTHETIC ERR-100 |
| CQBG |
FIRST END SWIVEL ACTION CAPABILITY |
NOT INCLUDED |
| CRBL |
SECOND END FITTING/COMPONENT AND MATERIAL |
COMPLETE FITTING BRASS, QQ-B-626, ALLOY 360, 1/2H |
| CQJX |
NOMINAL THREAD SIZE |
0.438 INCHES 1ST END |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND 1ST END |
| ADLH |
SECOND END FITTING SPEC/STD DATA |
MS39159-3 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
| CQJX |
NOMINAL THREAD SIZE |
0.125 INCHES 2ND END |
| MEDA |
MEDIA FOR WHICH DESIGNED |
FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| CQRB |
SEAT ANGLE |
45.0 DEGREES 1ST END |
| THSD |
THREAD SERIES DESIGNATOR |
UNF 1ST END |
| CQBD |
BURST TEST PRESSURE |
1700.0 POUNDS PER SQUARE INCH |
| ABKV |
OUTSIDE DIAMETER |
0.437 INCHES NOMINAL |
| AAJD |
THREAD CLASS |
2A 1ST END |
| AHNC |
CONNECTION STYLE |
FLARE 2ND END |
| AKUU |
END CONNECTION DESIGN |
STRAIGHT 1ST END |
| AKUU |
END CONNECTION DESIGN |
STRAIGHT 2ND END |
| CQBB |
SECOND END RELATIONSHIP WITH FIRST END |
NOT IDENTICAL |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND 2ND END |
| CRZY |
SECOND END SWIVEL ACTION CAPABILITY |
NOT INCLUDED |
| ADJM |
INNER CONVEYING TUBE MATERIAL |
RUBBER, SYNTHETIC |
| CMLP |
THREAD QUANTITY PER INCH |
20 1ST END |
| AHNC |
CONNECTION STYLE |
PLAIN 1ST END |
| CRJM |
OUTER COVERING ENVIRONMENTAL PROTECTION |
MILDEW RESISTANT AND OIL RESISTANT AND FUEL RESISTANT AND OZONE RESISTANT AND COLD RESISTANT |