| CRWL |
INSIDE SURFACE CONDITION |
SMOOTH |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
ROUND |
| ADUY |
CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH |
1.750 INCHES NOMINAL 1ST END |
| ABJH |
TEMP RATING |
-40.0 DEG FAHRENHEIT SINGLE RESPONSE AND 200.0 DEG FAHRENHEIT SINGLE RESPONSE |
| CQGM |
MAXIMUM OPERATING PRESSURE |
3000.0 POUNDS PER SQUARE INCH |
| AHNX |
BOLT HOLE DIAMETER |
0.781 INCHES NOMINAL 1ST END |
| CQCS |
LAYER COMPOSITION AND LOCATION |
2ND LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
| ABKV |
OUTSIDE DIAMETER |
2.661 INCHES MINIMUM AND 2.693 INCHES MAXIMUM |
| ABKU |
FLANGE THICKNESS |
1.440 INCHES NOMINAL 1ST END |
| AHNC |
CONNECTION STYLE |
PLAIN SWIVEL W/ GASKET GROOVE 1ST END |
| CRFY |
FLOW ANGLE |
90.0 DEGREES 1ST END |
| AKUT |
END FLANGE CONSTRUCTION |
SPLIT 1ST END |
| CQCS |
LAYER COMPOSITION AND LOCATION |
OUTER LAYER MOLDED RUBBER, SYNTHETIC ERR-100 |
| AARX |
INSIDE DIAMETER |
2.000 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
| CQCS |
LAYER COMPOSITION AND LOCATION |
3RD LAYER SPIRALLY LAID STEEL WIRE ERR-100 |
| CQBD |
BURST TEST PRESSURE |
12000.0 POUNDS PER SQUARE INCH |
| CRJM |
OUTER COVERING ENVIRONMENTAL PROTECTION |
HYDRAULIC SOLUTION RESISTANT |
| MEDA |
MEDIA FOR WHICH DESIGNED |
HYDRAULIC FLUID SINGLE RESPONSE |
| AKUU |
END CONNECTION DESIGN |
ELBOW 1ST END |
| ADUZ |
CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH |
3.812 INCHES NOMINAL 1ST END |
| ADLG |
FIRST END FITTING SPEC/STD DATA |
SAE J518 CODE 62 - 81343 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
| AWLS |
CONNECTION TYPE |
PLAIN FACE FLANGE 1ST END |
| AGFF |
FLANGE WIDTH |
4.400 INCHES NOMINAL 1ST END |
| AFQN |
FLANGE LENGTH |
5.250 INCHES NOMINAL 1ST END |
| CRXX |
MEASURING METHOD AND LENGTH |
72.000 INCHES NOMINAL OVERALL |
| CQBB |
SECOND END RELATIONSHIP WITH FIRST END |
IDENTICAL |
| AECS |
BOLT HOLE QUANTITY |
4 1ST END |
| ADLF |
HOSE OR TUBING SPEC/STD DATA |
MIL-H-24135/9, SIZE 32 - 81349 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |
| CTCJ |
FLANGE STYLE |
DOUBLE OVAL (SAE SPLIT TYPE FLANGE) 1ST END |
| ACKH |
MINIMUM INSIDE BENDING RADIUS |
25.000 INCHES |
| AGAV |
END ITEM IDENTIFICATION |
HYDRAULIC POWER UNIT |
| ADJM |
INNER CONVEYING TUBE MATERIAL |
RUBBER, SYNTHETIC |
| CQCS |
LAYER COMPOSITION AND LOCATION |
1ST LAYER SPIRALLY LAID STEEL WIRE ERR-100 |