| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
ALTERNATE OPERATING |
| ABRY |
LENGTH |
28.000 INCHES NOMINAL |
| FCLS |
FUNCTIONAL CLASSIFICATION |
AA-9.3 |
| NTRD |
ENTRY DATE |
70-04-01 |
| HGTH |
HEIGHT |
9.000 INCHES NOMINAL |
| AQXZ |
OPERATING TEST CAPABILITY |
MECHANICAL/PNEUMATIC INPUT REQUIREMENTS: HYDRAULIC PRESSURE AT 4500 PSI |
| RDAL |
REFERENCE DATA AND LITERATURE |
DRAWING 2-76611-1; TO 33D3-8-29-4 |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| AQXY |
TEST TYPE FOR WHICH DESIGNED |
FUNCTIONAL PERFORMANCE |
| ABGL |
WIDTH |
9.500 INCHES NOMINAL |
| ANPZ |
INCLOSURE FEATURE |
MULTIPLE ITEM W/CARRYING CASE |
| ACYN |
AC VOLTAGE RATING |
115.0 VOLTS NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
T38A AND F5A ACFT |
| FTLD |
FUNCTIONAL DESCRIPTION |
USED TO CHECK THE ELECTRO-MECHANICAL CONTROL VALVES AND THE HYDRAULIC ACTUATION OF THE PITCH AND YAW SERVO ACTUATORS IN THE T-38 TALON BASIC TRAINER FLIGHT CONTROL SYSTEM. PROVIDES A MTG BASE TO HOLD SERVO ACTUATOR CYLINDER,CONTROLS THE HYDRAULIC OIL COMING FROM THE HYDRAULIC TEST STAND,MEASURES THE MOVEMENT OF THE ACTUATOR ROD,PROVIDES A CONTROLLABLE SOURCE FOR THE ELECTRICAL SIGNALS USED TO OPERATE THE TRANSFER VALVE |
| FAAZ |
PHASE |
SINGLE |