| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
STAND ASSEMBLY,FUEL PRESSURE TEST |
| AGAV |
END ITEM IDENTIFICATION |
PW-TF30 ENGINES, FUEL MANIFOLD SYSTEM AND AFTERBURNER NOZZLE ACTUATOR |
| CBME |
CUBIC MEASURE |
97744.500 CUBIC INCHES |
| PKWT |
UNPACKAGED UNIT WEIGHT |
1000.000 POUNDS |
| AFJS |
PORTABILITY METHOD |
BRAKE TYPE CASTERS |
| RDAL |
REFERENCE DATA AND LITERATURE |
T.O. 33D4-6-310-11; NAVAIR17-15BD-25 |
| AJAF |
UNPACKAGED UNIT LENGTH |
53.500 INCHES NOMINAL |
| FTLD |
FUNCTIONAL DESCRIPTION |
TEST STAND IS USED TO LEAK TEST THE FUEL MANIFOLD SYSTEM AND AFTERBURNER NOZZLE ON THE PW-TF30 ENGINE |
| AJAH |
UNPACKAGED UNIT HEIGHT |
42.000 INCHES NOMINAL |
| ALQG |
CONTAINER TYPE |
ROLL CABINET |
| AJAG |
UNPACKAGED UNIT WIDTH |
43.500 INCHES NOMINAL |
| SUPP |
SUPPLEMENTARY FEATURES |
THE QUICK CONNECT FLEXIBLE HOSE LINES ARE NOT SUPPLIED WITH THE PWA15500A AND PWA15710 TEST STANDS HOWEVER THEY ARE AVAILABLE AS KIT ASSY PWA-15747; ELECTRICAL POWER REQUIREMENTS-220VAC, 3PHASE, 60 CYCLE, 7KVA; FUEL TANK CAPACITY- 20 GALLONS OF MIL-F-7024A TYPE 2 FUEL; STAND MAINTAINS FUEL BETWEEN 85 TO 90 DEG F UP TO AMBIENTS OF 100 DEG F |
| FEAT |
SPECIAL FEATURES |
THE TEST STAND IS A MOBILE STEEL STRUCTURE HOUSING FUEL CIRCUIT AND REFRIGERATION SYSTEM COMPONENTS AND THE NECESSARY WIRING, PLUMBING, CONTROLS AND INSTRUMENTATION NECESSARY FOR OPERATION; THE COMPLETE TEST STAND MEETS THE REQUIREMENTS FOR CLASS 1, GROUP D, HAZARDOUS LOCATION EQUIPMENT; CONNECTION TO THE TEST COMPONENT IS BY QUICK DISCONNECT FLEXIBLE HOSE LINES ON THE RIGHT SIDE OF THE TEST STAND ALONG WITH THE POWER INPUT CABLE |