| ALBY |
USAGE DESIGN |
AIRCRAFT HYDRAULIC SYSTEM |
| FREQ |
FREQUENCY IN HERTZ |
60.0 |
| CGYK |
ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE |
INCLUDED |
| CGYL |
FLOW CAPACITY RATING |
20.0 GALLONS PER MINUTE |
| FEAT |
SPECIAL FEATURES |
POWER PACK ALLOWS SYSTEM TO BE A DUAL SYSTEM; CONTROL SECTION IS 45.000 IN W,87.000 IN H,96.000 IN L; POWER PACK 76.000 IN W,66.000 IN H,64.000 IN L |
| BJDW |
MAXIMUM OPERATING PRESSURE |
5000.0 POUNDS PER SQUARE INCH |
| CGYM |
PRESSURE MANIFOLD SUBCIRCUIT |
NOT INCLUDED |
| FAAZ |
PHASE |
THREE |
| CHGR |
PRESSURE/SUCTION HOSE |
INCLUDED |
| AMQY |
INSTALLATION DESIGN |
FIXED |
| CHGQ |
FILTERING SYSTEM |
INCLUDED |
| AAYJ |
HYDRAULIC FLUID FLOW RATE |
20.0 GALLONS PER MINUTE |
| RDAL |
REFERENCE DATA AND LITERATURE |
T.O. 33D2-5-37-1 |
| ANCY |
HORSEPOWER RATING |
0.5 |
| ZZZV |
FSC APPLICATION DATA |
C-141 ACFT AGE |
| ACDC |
CURRENT TYPE |
AC |
| AYJM |
ACCUMULATOR |
INCLUDED |
| ATJK |
POWER SOURCE |
ELECTRIC MOTOR |
| AKCV |
DRIVE TYPE |
ELECTRIC MOTOR |
| FTLD |
FUNCTIONAL DESCRIPTION |
PROVIDES HYDRAULIC POWER TO TEST THE SPOILER ACTUATION SYSTEM OF THE C-141 AIRCRAFT |
| BGST |
PRESSURE RATING |
1000.0 POUNDS PER SQUARE INCH MINIMUM AND 3000.0 POUNDS PER SQUARE INCH MAXIMUM |
| ATPR |
MAXIMUM SPEED RATING IN RPM |
1725.0 |
| ELEC |
VOLTAGE IN VOLTS |
440.0 |