4920-01-205-1204 ( 2625985G002 , 2625985G001 , TS-4307/ALM )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 4920-01-205-1204 | 4920 | 012051204 | TEST STATION,ELECTRICAL-ELECTRON | 3918 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| FEAT | SPECIAL FEATURES | C/O TWO CABINENTS: CABINENT NO. 1 HOLDS OSCILLOSCOPE 180D/1808A/1825A,DIGITEC DIGITAL VOLTMETER 266,STORAGE DRAWER FOR ANCILLARY EQUIPMENT AND A CONTROL PANEL FOR CONTROLLING/MONITORING INPUT LINE LEVELS TO INDIVIDUAL POWER SUPPLIES; CABINENT NO. 2 CONTAINS VOLTAGE/LOAD SELECTOR PANEL AND POWER SUPPLY OUTPUT CONNECTOR PANEL; O/A DIM: 196.000 IN. W.,30.000 IN. H.,48.000 D.; WT: 2000 LBS; LOAD VOLTAGE: 185 V MAX; LOAD CURRENT: 140 AMPS MAX AT 5 V; OPERATING POWER REQUIREMENTS: AC; 118 V; 400 HZ; 3 PHASE; 115 V; 60 HZ; DC; 28 V |
| AGAV | END ITEM IDENTIFICATION | AN/ALQ-172 SE |
| FTLD | FUNCTIONAL DESCRIPTION | USED TO TEST THE LOW VOLTAGE POWER SUPPLY SRUS OF THE AN/ALQ-172(V),AND AN/ALQ-117 COUNTERMEASURES SETS |
| RDAL | REFERENCE DATA AND LITERATURE | DD 61 AEL-88-36 |
| ALCD | USAGE DESIGN | LOW VOLTAGE POWER SUPPLY |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 2625985G002 | 28527 | A | 2 | 3 | 4 | MG | |
| 2625985G001 | 28527 | A | 9 | 5 | 4 | MG | |
| TS-4307/ALM | 80058 | M | 2 | 5 | 4 | MG |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 2625985G002 | 28527 | ITT CORPORATION | A | A |
| 2625985G001 | 28527 | ITT CORPORATION | A | A |
| TS-4307/ALM | 80058 | JOINT ELECTRONICS TYPE DESIGNATI | A | M |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | 3 | X | B | 3 | 04/04/1 | N | 9031200000 | 3918 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DF | S | --MEW-E | L |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| B | U | N | 3 | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DF | FLZ | Y | 1 | EA | 0 | U | --MEW-E | L |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|