| FTLD |
FUNCTIONAL DESCRIPTION |
GENERATES A SWEEP WAVEFORM STARTING AT 100V AND SWEEPING AT A RATE OF 27V PER MILLISECOND; THE SWEEP STARTS WHEN A TRIGGER IS APPLIED AND WILL CONTINUE FOR A MINIMUM OF 2.5 MILLISECONDS; THE SWEEP CAN BE STOPPED AT ANY TIME BY THE APPLICATION OF A STOP-TRIGGER |
| AGTA |
BASIC SHAPE STYLE |
RECTANGULAR OR SQUARE |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
2.000 PULSES PER SECOND PUNCHED CARD MEGAHERTZ AND 400.000 PULSES PER SECOND DETACHABLE NECKBAND MEGAHERTZ |
| BHTB |
FREQUENCY PER CHANNEL |
0.0 HERTZ PUNCHED CARD MINIMUM AND 30.0 HERTZ DETACHABLE NECKBAND MINIMUM |
| BHTZ |
SIGNAL DATA TYPE PER CHANNEL |
OUTPUT CHANNEL PULSE |
| ABKW |
OVERALL HEIGHT |
1.880 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
3.220 INCHES NOMINAL |
| BHTN |
IMPEDANCE RATING PER CHANNEL |
330.000 OHMS OUTPUT CHANNEL |
| AMQY |
INSTALLATION DESIGN |
RACK |
| BKFB |
EXTERNAL DC OPERATING VOLTAGE IN VOLTS |
140.0 NOMINAL 2ND VOLTAGE |
| BJBQ |
OPERATING AC FREQUENCY IN HERTZ |
60.0 NOMINAL SINGLE VOLTAGE |
| BHTW |
PULSE PEAK AMPLITUDE PER CHANNEL |
95.000 VOLTS OUTPUT CHANNEL |
| BJBJ |
OUTPUT WAVE SHAPE |
SAWTOOTH |
| AFSU |
AVERAGE LIFE MEASUREMENT |
NOT RATED |
| BKFB |
EXTERNAL DC OPERATING VOLTAGE IN VOLTS |
250.0 NOMINAL 3RD VOLTAGE |
| ABHP |
OVERALL LENGTH |
3.750 INCHES NOMINAL |
| BHSX |
CIRCUIT CONSTRUCTION TYPE |
SOLID STATE |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| BHTS |
POLARITY PER CHANNEL |
NEGATIVE OUTPUT CHANNEL |
| BKFB |
EXTERNAL DC OPERATING VOLTAGE IN VOLTS |
-140.0 NOMINAL 1ST VOLTAGE |
| BKFC |
EXTERNAL AC OPERATING VOLTAGE IN VOLTS |
6.1 NOMINAL SINGLE VOLTAGE |
| AGAV |
END ITEM IDENTIFICATION |
AN/FPS-6 |
| FAAZ |
PHASE |
SINGLE |
| BHTP |
PULSE DURATION PER CHANNEL |
2.500 MILLISECONDS NOMINAL OUTPUT CHANNEL |