| AGTA |
BASIC SHAPE STYLE |
RECTANGULAR OR SQUARE |
| BKFC |
EXTERNAL AC OPERATING VOLTAGE IN VOLTS |
105.0 MINIMUM SINGLE VOLTAGE AND 125.0 MAXIMUM SINGLE VOLTAGE |
| ABMK |
OVERALL WIDTH |
18.000 INCHES NOMINAL |
| BHTN |
IMPEDANCE RATING PER CHANNEL |
50.000 OHMS OPERATING CHANNEL |
| AFSU |
AVERAGE LIFE MEASUREMENT |
NOT RATED |
| SUPP |
SUPPLEMENTARY FEATURES |
1 CHANNEL; 1 OUTPUT PER CHANNEL; INPUT CENTER FREQ 160 MHZ PORM 150 KHZ; OUTPUT CENTER FREQ 45 MHZ PORM 150 KHZ; INPUT LEVEL -15 DBM TO NOISE; OUTPUT LEVEL 0 DBM TO -55 DBM; BANDWIDTH (3 DB) 10 MHZ MIN; SIGNAL PORT RETURN LOSS 15 DB 1:44:1 VSWR; NOISE FIGURE 12 DB; IMAGE REJECTION 50 DB MIN; SIGNAL AND REFERENCE CONNECTORS: BNC JACKS,A BNC PORT SHALL BE PROVIDED ON THE DOWN CONVERTER FOR THE EXTERNAL REFERENCE SIGNAL; AM/PM CONVERSION 0.2 DEG. PER DB; CONVERSION CIRCUIT SYNTHESIZED LOCAL OSCIALLATOR; INTERNAL REFERENCE 5 MHZ PORM .005 PERCENT; INTERNAL REF. PHASE NOISE 100 DBC/HZ AT 10 KHZ OFFSET; SPURIOUS RESPONSE -50 DBC MAX; GROUP DELAY PORM 50 NANO SECONDS MAX |
| AMQY |
INSTALLATION DESIGN |
MODULE |
| AGAV |
END ITEM IDENTIFICATION |
AN/FSQ-151(V) ARTS |
| ABKW |
OVERALL HEIGHT |
1.750 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
19.000 INCHES NOMINAL |
| BHSX |
CIRCUIT CONSTRUCTION TYPE |
SOLID STATE |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AFGA |
OPERATING TEMP RANGE |
+0.0/+50.0 DEG CELSIUS |
| BJBQ |
OPERATING AC FREQUENCY IN HERTZ |
57.0 MINIMUM SINGLE VOLTAGE AND 63.0 MAXIMUM SINGLE VOLTAGE |
| FAAZ |
PHASE |
SINGLE |