5895-01-409-0676 ( M79C-200 , M79C-200 , 233867-1 , M79C-200 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5895-01-409-0676 | 5895 | 014090676 | MIXER STAGE,FREQUENCY | 0033 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AQZF | CONTROL TYPE | REMOTE |
| BHTJ | AVERAGE POWER RATING PER CHANNEL | 150.0 MILLIWATTS INPUT |
| AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE |
| AFGA | OPERATING TEMP RANGE | -54.0/+100.0 DEG CELSIUS |
| AMQY | INSTALLATION DESIGN | MECHANICAL |
| ABHP | OVERALL LENGTH | 1.638 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 0.375 INCHES NOMINAL |
| ZZZV | FSC APPLICATION DATA | COMMUNICATION EQUIPMENT, MISC. |
| AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED |
| BHSX | CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
| AKNA | INCLOSURE TYPE | ENCASED |
| BHTD | FREQUENCY ADJUSTMENT TYPE | CONTINUOUS |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| AFJQ | STORAGE TEMP RANGE | -65.0/+100.0 DEG CELSIUS |
| ABMK | OVERALL WIDTH | 1.223 INCHES NOMINAL |
| ALBM | OPERATING CONTROL METHOD | AUTOMATIC |
| FEAT | SPECIAL FEATURES | HANDLE WITH CAUTION TO AVOID DAMAGE FROM ELECTRO-STATIC DISCHARGE |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| M79C-200 | 94987 | A | 2 | 5 | 5 | ZZ | |
| M79C-200 | 1BWN1 | A | 1 | C | 9X | 5 | ZZ |
| 233867-1 | 94987 | A | 2 | 3 | E | ZZ | |
| M79C-200 | 14482 | F | 9 | 5 | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| M79C-200 | 94987 | CUBIC DEFENSE APPLICATIONS INC. | A | A |
| M79C-200 | 1BWN1 | COBHAM ELECTRONIC SYSTEMS INC. | A | A |
| 233867-1 | 94987 | CUBIC DEFENSE APPLICATIONS INC. | A | A |
| M79C-200 | 14482 | WATKINS-JOHNSON CO | A | F |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | Y | A | 03/03/1 | B | N | 9030908040 | 0033 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DS | N | I | |||
| DF | N | SF9---N | F |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | 0 | Y | B |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | J | 0 | EA | 0 | U | D | ||
| DF | SMS | J | 0 | EA | 0 | U | SF9---N | F |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|