| ABJT |
TERMINAL LENGTH |
2.000 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-2.8/+2.8 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
373.7 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
BEAD |
| AEHZ |
MAXIMUM OPERATING TEMP |
300.0 DEG CELSIUS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-2.5/+2.5 1ST RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.016 INCHES NOMINAL |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.2 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
15.000 KILOHMS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-40.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
33.8 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-2.0/+2.0 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-2.0/+2.0 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
300.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| ADAR |
BODY OUTSIDE DIAMETER |
0.043 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-2.0/+2.0 5TH RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
8.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
5.8 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-2.1/+2.1 2ND RESISTANCE-TEMPERATURE POINT |
| TEST |
TEST DATA DOCUMENT |
82577-954026 DRAWING |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
371.2 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
0.7 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
44.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |