5905-00-116-8568 ( RCR20C722G2 , MIL-R-39008/2 , 1-244-894-51 , RCR20GF752JM , 7100-0049-225 , 060-07504-042 , RCR20G752JM , M1-75255 , RCR20G752JP , RCR20G752JR , RC20GF752J , 64A7A68-752 , 400-612-084 , 10011-752 , 585326-157 , 585326-158 , MS35043-108 , 1352-7501 , 280-1145P105 , 108910 , RCR20G752JS , 1352-8201 , RC207500 , RCR20G752KM , RL20GF752J , 404-75251 , RCR20G762JS , 418766-108 , 4171306-662 , 151-10386 , 041-361 , 400-612-084 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5905-00-116-8568 | 5905 | 001168568 | RESISTOR,FIXED,COMPOSITION | 0012 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AAPP | ELECTRICAL RESISTANCE | 7.500 KILOHMS |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 130.0 |
| ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
| STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
| ABPM | BODY DIAMETER | 0.138 INCHES NOMINAL |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.500 FREE AIR |
| AARB | TERMINAL TYPE | WIRE LEAD |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/+5.000 |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-39008 SPECIFICATION |
| ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39008/2 GOVERNMENT SPECIFICATION |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| RCR20C722G2 | 81349 | M | 1 | C | AC | 6 | ZZ |
| MIL-R-39008/2 | 81349 | M | 1 | 4 | 3 | TX | |
| 1-244-894-51 | 56614 | A | 1 | C | AC | 6 | ZZ |
| RCR20GF752JM | 81349 | M | 1 | C | AC | 6 | ZZ |
| 7100-0049-225 | 06032 | A | 1 | C | 5 | 48 | |
| 060-07504-042 | 12131 | A | 1 | C | AH | 5 | TX |
| RCR20G752JM | 81349 | M | 9 | 5 | 3 | TX | |
| M1-75255 | 54418 | A | 1 | C | AF | 5 | TX |
| RCR20G752JP | 81349 | M | 9 | 5 | 3 | TX | |
| RCR20G752JR | 81349 | M | 9 | 5 | 3 | TX | |
| RC20GF752J | 81349 | M | 9 | 5 | 3 | TX | |
| 64A7A68-752 | 53711 | A | 1 | C | AC | 6 | ZZ |
| 400-612-084 | A1997 | A | 2 | 5 | 3 | ZG | |
| 10011-752 | 52542 | F | 1 | C | AC | 5 | TX |
| 585326-157 | 49956 | A | 1 | C | AC | 6 | ZZ |
| 585326-158 | 49956 | A | 1 | C | AC | 6 | ZZ |
| MS35043-108 | 96906 | M | 1 | C | AC | 6 | ZZ |
| 1352-7501 | 15455 | A | 1 | C | AC | 6 | ZZ |
| 280-1145P105 | 49956 | A | 1 | C | AH | 4 | 48 |
| 108910 | 89536 | A | 8 | E | 5 | ZZ | |
| RCR20G752JS | 81349 | M | 2 | 2 | 3 | TX | |
| 1352-8201 | 15455 | A | 1 | C | AC | 6 | ZZ |
| RC207500 | 78488 | A | 1 | C | AC | 6 | ZZ |
| RCR20G752KM | 81349 | M | 1 | C | AC | 6 | ZZ |
| RL20GF752J | 81349 | M | 9 | 5 | 6 | TX | |
| 404-75251 | 13848 | F | 1 | C | AH | 5 | TX |
| RCR20G762JS | 81349 | M | 1 | C | AC | 6 | ZZ |
| 418766-108 | 96214 | A | 1 | C | AH | 5 | TX |
| 4171306-662 | 05869 | A | 2 | 5 | 6 | 9Z | |
| 151-10386 | 54407 | A | 1 | C | AW | E | TX |
| 041-361 | 92739 | R | 1 | C | AF | 6 | TX |
| 400-612-084 | C3141 | A | 2 | 5 | 3 | ZG |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| RCR20C722G2 | 81349 | MILITARY SPECIFICATIONS | A | M |
| MIL-R-39008/2 | 81349 | MILITARY SPECIFICATIONS | A | M |
| 1-244-894-51 | 56614 | VIDEOTEK INC. | A | A |
| RCR20GF752JM | 81349 | MILITARY SPECIFICATIONS | A | M |
| 7100-0049-225 | 06032 | ANTENNA PRODUCTS CORPORATION | A | A |
| 060-07504-042 | 12131 | LH ENTERPRISE | A | A |
| RCR20G752JM | 81349 | MILITARY SPECIFICATIONS | A | M |
| M1-75255 | 54418 | MILTOPE CORPORATION | A | A |
| RCR20G752JP | 81349 | MILITARY SPECIFICATIONS | A | M |
| RCR20G752JR | 81349 | MILITARY SPECIFICATIONS | A | M |
| RC20GF752J | 81349 | MILITARY SPECIFICATIONS | A | M |
| 64A7A68-752 | 53711 | NAVAL SEA SYSTEMS COMMAND | A | A |
| 400-612-084 | A1997 | ELETTRONICA SPA | E | A |
| 10011-752 | 52542 | SYSTRON-DONNER CORP | A | F |
| 585326-157 | 49956 | RAYTHEON COMPANY | A | A |
| 585326-158 | 49956 | RAYTHEON COMPANY | A | A |
| MS35043-108 | 96906 | MILITARY STANDARDS | A | M |
| 1352-7501 | 15455 | ELGENCO INC | A | A |
| 280-1145P105 | 49956 | RAYTHEON COMPANY | A | A |
| 108910 | 89536 | FLUKE CORPORATION | A | A |
| RCR20G752JS | 81349 | MILITARY SPECIFICATIONS | A | M |
| 1352-8201 | 15455 | ELGENCO INC | A | A |
| RC207500 | 78488 | STACKPOLE CORP THE | A | A |
| RCR20G752KM | 81349 | MILITARY SPECIFICATIONS | A | M |
| RL20GF752J | 81349 | MILITARY SPECIFICATIONS | A | M |
| 404-75251 | 13848 | JOHNSON E F CO | A | F |
| RCR20G762JS | 81349 | MILITARY SPECIFICATIONS | A | M |
| 418766-108 | 96214 | RAYTHEON COMPANY | F | A |
| 4171306-662 | 05869 | RAYTHEON COMPANY | A | A |
| 151-10386 | 54407 | POWER-ONE DC POWER SUPPLIES | A | A |
| 041-361 | 92739 | AMPEX SYSTEMS CORP | A | R |
| 400-612-084 | C3141 | ELETTRONICA GMBH | E | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | A | 1 | 10/11/1 | B | N | 8533290000 | 0012 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DM | Z | 15B2T-- | M | ||
| DF | N | SF9EH-N | F | ||
| GP | ------- | C | |||
| DN | 9B----- | N | |||
| DS | N | I | |||
| DA | Z | Q2200X- | A |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | 0 | X | B |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | SMS | D | A | EA | 0 | U | 9B----- | N | |
| DS | SMS | D | A | EA | 0 | U | D | ||
| DA | SMS | D | A | EA | 0 | U | Z | Q2200X- | A |
| DM | SMS | D | A | EA | 0 | U | Z | 15B2T-- | M |
| GP | SMS | D | A | EA | 0 | U | ------- | C | |
| DF | SMS | D | A | EA | 0 | U | SF9EH-N | F |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| Q | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 062960 | X | 35140 | P | 658 | 3 | 9 | A | H | Z | REOSTATS/PARTS NOI |