| AEBT |
TERMINAL DIAMETER |
0.004 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
66.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-25.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
315.6 DEG CELSIUS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-20.0/+20.0 |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
2.0 |
| ADAR |
BODY OUTSIDE DIAMETER |
0.043 INCHES NOMINAL |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
12.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
27.6 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
SEALED OR COATED BEAD |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.4 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
6.1 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
710.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
200.000 KILOHMS |
| ABJT |
TERMINAL LENGTH |
0.375 INCHES NOMINAL |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
0.7 |