| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
19.80 |
| ADAT |
BODY WIDTH |
0.200 INCHES MAXIMUM |
| CQWD |
ZERO POWER RESISTANCE |
1.000 KILOHMS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
2.9 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
54.9 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 DEG CELSIUS |
| STYL |
STYLE DESIGNATOR |
SPHERICAL |
| ADAR |
BODY OUTSIDE DIAMETER |
0.180 INCHES MAXIMUM |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
350.00 MILLIWATTS |
| AEBT |
TERMINAL DIAMETER |
0.010 INCHES MINIMUM AND 0.016 INCHES MAXIMUM |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
5.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
184.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
405.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
92.3 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| ABJT |
TERMINAL LENGTH |
1.500 INCHES MINIMUM |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
5.8 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
80.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| TEST |
TEST DATA DOCUMENT |
00752-361254 DRAWING |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
50.3 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.0/+15.0 ALL RESISTANCE-TEMPERATURE POINTS |