| CSCY |
TEMP COEFFICIENT OF RESISTANCE WIRE PER SECTION IN PPM PER DEG CELSIUS |
-50.0/+50.0 SINGLE SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
1.000 KILOHMS SINGLE SECTION |
| AAPN |
SECTION QUANTITY |
1 |
| AGTP |
LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS |
0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
ZZZY |
| ADAQ |
BODY LENGTH |
0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
| ABHP |
OVERALL LENGTH |
1.035 INCHES MINIMUM AND 1.065 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH |
0.165 INCHES MINIMUM AND 0.175 INCHES MAXIMUM |
| ZZZY |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS |
QUALITY CONTROLLED FOR POLARIS |
| AEDZ |
SHAFT BEARING TYPE |
BEARING |
| ABJT |
TERMINAL LENGTH |
6.000 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
0.305 INCHES MINIMUM AND 0.325 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
0.165 INCHES MINIMUM AND 0.175 INCHES MAXIMUM |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABKW |
OVERALL HEIGHT |
0.305 INCHES MINIMUM AND 0.325 INCHES MAXIMUM |
| AAQL |
BODY STYLE |
RECTANGULAR W/MOUNTING HOLES/SLOTS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
3 WIRE LEAD |
| AKPV |
MOUNTING FACILITY QUANTITY |
2 |
| APXH |
TERMINAL LOCATION |
REAR END |
| CRGD |
POWER DISSIPATION RATING PER SECTION IN WATTS |
1.0 FREE AIR SINGLE SECTION |
| CQGN |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER |
175.0 SINGLE SECTION |
| AEFD |
ACTUATOR TYPE |
SINGLE SHAFT |
| CRSS |
RESISTANCE TOLERANCE PER SECTION IN PERCENT |
-5.0/+5.0 SINGLE SECTION |
| CSDH |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER |
70.0 SINGLE SECTION |
| AEDX |
SHAFT STYLE |
ROUND, SLOTTED |
| CSDL |
STANDARD TAPER CURVE PER SECTION |
A SINGLE SECTION |
| ABXF |
SHAFT LENGTH |
0.040 INCHES MINIMUM AND 0.060 INCHES MAXIMUM |
| ABWV |
SHAFT DIAMETER |
0.120 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
| ABTB |
MOUNTING HOLE DIAMETER |
0.086 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
UNTHREADED HOLE |