| ABJT |
TERMINAL LENGTH |
2.000 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
0.2 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
5.000 OHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
22.8 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
2.3 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| ADAT |
BODY WIDTH |
0.080 INCHES NOMINAL |
| ADAR |
BODY OUTSIDE DIAMETER |
0.500 INCHES NOMINAL |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
15.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-3.30 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
0.7 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
70.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
0.4 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
UNINCLOSED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.2 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 DEG CELSIUS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
159.5 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.025 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| STYL |
STYLE DESIGNATOR |
DISK |