| CQWD |
ZERO POWER RESISTANCE |
1.000 KILOHMS |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
100.0 |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| ADAT |
BODY WIDTH |
0.135 INCHES MAXIMUM |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
56.7 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
2.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| ABMK |
OVERALL WIDTH |
0.270 INCHES MAXIMUM |
| ABJT |
TERMINAL LENGTH |
2.150 INCHES MINIMUM |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
13.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-3.83 |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
187.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| ADAR |
BODY OUTSIDE DIAMETER |
0.280 INCHES MINIMUM AND 0.320 INCHES MAXIMUM |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
7.5 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| STYL |
STYLE DESIGNATOR |
DISK |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-14.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |