| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-51.1 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| ABJT |
TERMINAL LENGTH |
1.375 INCHES NOMINAL |
| AEWK |
MAXIMUM CURRENT RATING |
25.00 AMPERES |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
2.25 WATTS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| ADAR |
BODY OUTSIDE DIAMETER |
0.219 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
93.3 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
ROD |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
60.0 |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
54.4 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
125.0 DEG CELSIUS |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
5.5 |
| ADAQ |
BODY LENGTH |
0.906 INCHES NOMINAL |
| CQWD |
ZERO POWER RESISTANCE |
4.600 KILOHMS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
18.3 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.020 INCHES NOMINAL |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
68.6 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
16.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-17.8 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
200.0 DEG CELSIUS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |