| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-21.5 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| CQWD |
ZERO POWER RESISTANCE |
9.600 OHMS |
| ADAT |
BODY WIDTH |
0.150 INCHES MAXIMUM |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
37.8 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
0.9 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
SPHERICAL |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
4.1 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
104.4 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEBT |
TERMINAL DIAMETER |
0.031 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| ADAR |
BODY OUTSIDE DIAMETER |
0.510 INCHES MAXIMUM |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
70.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
6.1 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| ABJT |
TERMINAL LENGTH |
2.000 INCHES MINIMUM |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
1.50 WATTS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |