| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| CRYY |
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER |
0.190 INCHES |
| STYL |
STYLE DESIGNATOR |
WASHER ASSY/SINGLE END |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-18.9/+18.9 9TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-14.2/+14.2 3RD RESISTANCE-TEMPERATURE POINT |
| AASA |
THREAD LENGTH |
0.312 INCHES NOMINAL |
| CQWD |
ZERO POWER RESISTANCE |
415.000 OHMS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB, SOLDER LUG |
| CBME |
CUBIC MEASURE |
0.225 CUBIC INCHES |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-17.8/+17.8 8TH RESISTANCE-TEMPERATURE POINT |
| ADEM |
WASHER THICKNESS |
0.191 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-21.5 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
24.7 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.1/+15.1 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
62.2 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| ABHP |
OVERALL LENGTH |
2.125 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
37.8 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
150.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.4 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.9/+16.9 7TH RESISTANCE-TEMPERATURE POINT |
| ABKW |
OVERALL HEIGHT |
1.125 INCHES NOMINAL |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
232.4 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
104.4 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| ABDN |
TERMINAL SURFACE TREATMENT |
SOLDER |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
4.4 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| PKWT |
UNPACKAGED UNIT WEIGHT |
15.667 GRAMS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-40.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
UNINCLOSED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
55.0 |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNF |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
39.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
13.9 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
7.5 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 DEG CELSIUS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-13.7/+13.7 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-12.6/+12.6 4TH RESISTANCE-TEMPERATURE POINT |
| CGGK |
MOUNTING THREAD QUANTITY |
32 PER INCH |
| ABMK |
OVERALL WIDTH |
0.750 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.6/+16.6 2ND RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-18.9/+18.9 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
149.4 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| ADAR |
BODY OUTSIDE DIAMETER |
0.750 INCHES NOMINAL |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
14.1 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-20.1/+20.1 10TH RESISTANCE-TEMPERATURE POINT |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| ABJT |
TERMINAL LENGTH |
0.688 INCHES NOMINAL |