| ADAT |
BODY WIDTH |
0.260 INCHES MAXIMUM |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
6.3 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
0.50 WATTS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| CQWD |
ZERO POWER RESISTANCE |
68.000 OHMS |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-19.80 |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 DEG CELSIUS |
| STYL |
STYLE DESIGNATOR |
SPHERICAL |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
5.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.7 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-5.0/+5.0 2ND RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
392.3 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
27.5 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-1.0/+1.0 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-5.0/+5.0 4TH RESISTANCE-TEMPERATURE POINT |
| ABJT |
TERMINAL LENGTH |
1.500 INCHES MINIMUM |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-7.0/+7.0 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
12.5 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 1ST RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
80.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.020 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-T-23648/1 SPECIFICATION |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.4 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| ADAR |
BODY OUTSIDE DIAMETER |
0.250 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-3.0/+3.0 3RD RESISTANCE-TEMPERATURE POINT |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |