| ADAQ |
BODY LENGTH |
0.390 INCHES MINIMUM AND 0.430 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
75.0 |
| CQWD |
ZERO POWER RESISTANCE |
1.012 KILOHMS |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 DEG CELSIUS |
| STYL |
STYLE DESIGNATOR |
ROD |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
60.0 |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
5.0 |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEBT |
TERMINAL DIAMETER |
0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
500.00 MILLIWATTS |
| ABJT |
TERMINAL LENGTH |
1.250 INCHES MINIMUM |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-T-23648 SPECIFICATION |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS ALL RESISTANCE-TEMPERATURE POINTS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.012 KILOHMS ALL RESISTANCE-TEMPERATURE POINTS |
| ADAR |
BODY OUTSIDE DIAMETER |
0.120 INCHES MINIMUM AND 0.160 INCHES MAXIMUM |