| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
502.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
200.000 OHMS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.7/+16.7 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
124.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
28.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-14.2/+14.2 6TH RESISTANCE-TEMPERATURE POINT |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
4.0 |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
13.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.2 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-17.9/+17.9 8TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.2/+16.2 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
40.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-40.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
42.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.3/+10.3 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-20.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| PKWT |
UNPACKAGED UNIT WEIGHT |
0.600 GRAMS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-18.6/+18.6 1ST RESISTANCE-TEMPERATURE POINT |
| ADAT |
BODY WIDTH |
0.110 INCHES NOMINAL |
| ABDN |
TERMINAL SURFACE TREATMENT |
SOLDER |
| ABJT |
TERMINAL LENGTH |
1.500 INCHES MINIMUM |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
120.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| CBME |
CUBIC MEASURE |
0.00073 CUBIC INCHES |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-3.40 |
| AEBT |
TERMINAL DIAMETER |
0.013 INCHES NOMINAL |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
18.0 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
12.0 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
60.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
140.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
20.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.3 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 DEG CELSIUS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
80.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
70.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
260.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| ADAR |
BODY OUTSIDE DIAMETER |
0.100 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-13.1/+13.1 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-19.6/+19.6 9TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-20.9/+20.9 10TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-12.7/+12.7 5TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
DISK |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |