| ABJT |
TERMINAL LENGTH |
2.000 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| CBME |
CUBIC MEASURE |
0.00003 CUBIC INCHES |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
280.0 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
1.4 |
| CQWD |
ZERO POWER RESISTANCE |
100.000 KILOHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.0 MEGOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEWK |
MAXIMUM CURRENT RATING |
60.00 MILLIAMPERES |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.8 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.8 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
460.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
15.0 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
35.0 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-25.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.006 INCHES NOMINAL |
| STYL |
STYLE DESIGNATOR |
SQUARE OR RECTANGULAR WAFER |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-50.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-5.40 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| ABDN |
TERMINAL SURFACE TREATMENT |
SOLDER |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| ADAT |
BODY WIDTH |
0.050 INCHES NOMINAL |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
490.0 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
UNINCLOSED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
175.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 DEG CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
850.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| ADAU |
BODY HEIGHT |
0.012 INCHES NOMINAL |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
3.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
200.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| PKWT |
UNPACKAGED UNIT WEIGHT |
1.400 GRAMS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| ADAQ |
BODY LENGTH |
0.050 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
9.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |