| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
742.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-13.2/+13.2 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.0 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
100.000 OHMS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-20.6/+20.6 10TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
29.2 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
122.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.8/+16.8 2ND RESISTANCE-TEMPERATURE POINT |
| ADAR |
BODY OUTSIDE DIAMETER |
0.220 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-14.3/+14.3 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
40.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-21.6/+21.6 1ST RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-12.0/+12.0 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
9.2 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.006 INCHES NOMINAL |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.9/+16.9 9TH RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
18.0 |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-3.10 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-20.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| ABDN |
TERMINAL SURFACE TREATMENT |
SOLDER |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
7.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| ABJT |
TERMINAL LENGTH |
1.500 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.4/+10.4 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-40.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
282.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
60.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
57.6 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| CBME |
CUBIC MEASURE |
0.00114 CUBIC INCHES |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 DEG CELSIUS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
15.7 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
20.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
2.2 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| PKWT |
UNPACKAGED UNIT WEIGHT |
0.114 GRAMS |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
7.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
80.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| ADAT |
BODY WIDTH |
0.030 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-11.8/+11.8 6TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
DISK |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.5/+15.5 8TH RESISTANCE-TEMPERATURE POINT |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |