| AAPP |
ELECTRICAL RESISTANCE |
499.000 KILOHMS |
| AAQH |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS |
-55.0/+175.0 |
| AAPE |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS |
-50.0/+50.0 |
| AAQG |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER |
175.0 |
| ABJT |
TERMINAL LENGTH |
3.500 INCHES MINIMUM AND 4.900 INCHES MAXIMUM |
| FEAT |
SPECIAL FEATURES |
M22759/16 LEAD WIRES SOLDERED OR CRIMPED TO RESISTOR LEADS; INSULATION TUBING OVER RESISTOR BODY AND LEADS |
| AAQZ |
INCLOSURE METHOD |
ENCAPSULATED |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AAQF |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER |
125.0 |
| CBME |
CUBIC MEASURE (NON-CORE) |
0.005 CUBIC INCHES |
| ABPM |
BODY DIAMETER |
0.125 INCHES NOMINAL |
| TEST |
TEST DATA DOCUMENT |
97499-110-182 DRAWING |
| PKWT |
UNPACKAGED UNIT WEIGHT |
1.0 GRAMS |
| STYL |
STYLE DESIGNATOR |
AXIAL TERMINAL EACH END |
| AAPQ |
RESISTANCE TOLERANCE IN PERCENT |
-1.000/+1.000 |
| AEFB |
POWER DISSIPATION RATING IN WATTS |
0.125 FREE AIR |
| AARB |
TERMINAL TYPE |
WIRE LEAD |
| ADAQ |
BODY LENGTH |
0.375 INCHES NOMINAL |