| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-4.40 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-1.8/+1.8 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
27.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-0.57/+0.57 9TH RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
5.000 KILOHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
5.0 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
| ABHP |
OVERALL LENGTH |
4.433 INCHES MINIMUM AND 4.443 INCHES MAXIMUM |
| CBME |
CUBIC MEASURE |
1.041 CUBIC INCHES |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
30.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-1.4/+1.4 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
4.02 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-2.0/+2.0 10TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
PROBE |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
16.43 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-20.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| ASDB |
WIDTH ACROSS FLATS |
0.807 INCHES MINIMUM AND 0.817 INCHES MAXIMUM |
| CRYY |
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER |
0.438 INCHES |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-0.84/+0.84 |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-0.94/+0.94 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
48.15 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
89.5 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-0.82/+0.82 7TH RESISTANCE-TEMPERATURE POINT |
| ADAQ |
BODY LENGTH |
3.995 INCHES MINIMUM AND 4.005 INCHES MAXIMUM |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
9.965 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJH |
PROBE DIAMETER |
0.308 INCHES MINIMUM AND 0.318 INCHES MAXIMUM |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-10.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
25.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| ABJT |
TERMINAL LENGTH |
0.433 INCHES MINIMUM AND 0.443 INCHES MAXIMUM |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNEF |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-0.84/+0.84 6TH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-0.87/+0.87 5TH RESISTANCE-TEMPERATURE POINT |
| CGGK |
MOUNTING THREAD QUANTITY |
20 PER INCH |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
60.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 DEG CELSIUS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
336.0 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
20.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, PLUG |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-1.0/+1.0 3RD RESISTANCE-TEMPERATURE POINT |
| AEJG |
PROBE LENGTH |
2.995 INCHES MINIMUM AND 3.005 INCHES MAXIMUM |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-0.7/+0.7 8TH RESISTANCE-TEMPERATURE POINT |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
150.00 MILLIWATTS |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
10.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.235 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
6.23 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |