| AGAV |
END ITEM IDENTIFICATION |
6625-01-144-4481 TEST SET,RADIO |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
11.1 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
400.0 DEG CELSIUS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
2.1 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| ADAQ |
BODY LENGTH |
0.150 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| ADAR |
BODY OUTSIDE DIAMETER |
0.070 INCHES NOMINAL |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
200.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
60.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
2.000 KILOHMS |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
5.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
101.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
8.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
400.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
2.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
300.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| STYL |
STYLE DESIGNATOR |
BEAD TYPE EVACUATED OR GAS FILLED ENVELOPE |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.020 INCHES NOMINAL |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0/+10.0 |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
5.8 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
820.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
108.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
23.2 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| ABJT |
TERMINAL LENGTH |
1.125 INCHES NOMINAL |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
250.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
364.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |