| AEHX |
MAXIMUM POWER DISSIPATION RATING |
0.50 MICROWATTS |
| ADAT |
BODY WIDTH |
0.260 INCHES MAXIMUM |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
93.84 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| CQWD |
ZERO POWER RESISTANCE |
510.000 OHMS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
206.55 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
25.653 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 DEG CELSIUS |
| STYL |
STYLE DESIGNATOR |
SPHERICAL |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-23648 SPECIFICATION |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
5.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 DEG CELSIUS |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.4535 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-1.0/+1.0 |
| ABJT |
TERMINAL LENGTH |
1.500 INCHES MINIMUM |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
80.0 |
| ADAR |
BODY OUTSIDE DIAMETER |
0.200 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
27.999 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
47.073 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.180 INCHES MAXIMUM |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
2.9427 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEBT |
TERMINAL DIAMETER |
0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-23648/1 GOVERNMENT SPECIFICATION |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |