5905-01-484-9702 ( MSP10A-01-103J-S101 , 12273308 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5905-01-484-9702 | 5905 | 014849702 | RESISTOR NETWORK,FIXED,FILM | 3206 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 9 EACH RESISTOR |
| AGAV | END ITEM IDENTIFICATION | M-1 ABRAMS TANK |
| ADAQ | BODY LENGTH | 1.050 INCHES MAXIMUM |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+150.0 |
| STYL | STYLE DESIGNATOR | SINGLE INLINE |
| ADAU | BODY HEIGHT | 0.125 INCHES MAXIMUM |
| AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -200.0/+200.0 |
| AAPP | ELECTRICAL RESISTANCE | 10.000 KILOHMS |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | LADDER NETWORK |
| ABJT | TERMINAL LENGTH | 0.175 INCHES MINIMUM |
| ADAT | BODY WIDTH | 0.350 INCHES MAXIMUM |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.125 TOTAL NETWORK |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/+5.000 |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
| AARB | TERMINAL TYPE | PIN |
| AFWW | TERMINAL WIDTH | 0.020 INCHES NOMINAL |
| AARA | TERMINAL QUANTITY | 10 |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| MSP10A-01-103J-S101 | 91637 | A | 2 | 5 | 5 | ZZ | |
| 12273308 | 19207 | A | 2 | 3 | A | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| MSP10A-01-103J-S101 | 91637 | VISHAY DALE ELECTRONICS INC. | A | A |
| 12273308 | 19207 | U S ARMY TANK AUTOMOTIVE COMMAND | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | B | 3 | 05/11/2 | A | N | 8533100057 | 3206 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DA | Z | Q2200X- | A | ||
| DS | N | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| B | A | N | 0 | X | A |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DA | SMS | J | 1 | EA | 0 | U | Z | Q2200X- | A |
| DS | SMS | J | 1 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| Q | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|