5910-00-007-2002 ( 906D715-27 , 15-03-113 , CS13BD225K , 1500225 , CS13BD225M , SNS225A020MI , 037-367 , SCM225FP006A2 , 117002-0029 , 601-0100725 , TAS225K020P1A , CSR13E225K , CSR13E225KS , M39003-01-2764 , 100100 , 7902696-29 , 15T225M20 , CSR13E255K , 150D225X0020A2 , TS1-020-225-10 , 5060-739 , TAS225M020P0A , 35-1485 , 77E085P132 , 045-001520-276 , CSR13BE225K , 10215-0027 , 7890456-169 , M39003/1-2763 , SCM225FP006A2 , 906D715-27 , 825567-1073 , SCM225FR020D4 , 5496267P13 , CSR13E225KM , 096-1007-00 , 2106W21P014 , 150D225X9020A2B , A19908-54 , M39003/01-3003 , 624GA00-225K , 1782933-50 , SNS225A020K1 , 150D225X9015A0 , CS12BE225M , CSR13E225KP , 184-9086-440 , 184-9086-430 , CS13E225K , CSR13E225MM , CS2118-27 , CS13EE225K , T212A225K020SS , 2503220-27 , 11-49012-06 , 150D225X9020CD2 , MILC39003-1 , M39003-01-2283 , 17706704 , P15002314 , 6320-0013 , 23-29908A66 )

NSN Information
NSN FSC NIIN Item Name INC
5910-00-007-2002 5910 000072002 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
CQBQ CAPACITANCE VALUE PER SECTION 2.200 MICROFARADS SINGLE SECTION
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 4.0000
AARH RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.0010
CWSZ CASE INSULATION MATERIAL PLASTIC
CQLH DC LEAKAGE AT MAXIMUM OPERATING TEMP 8.0 MICROAMPERES
CWQH DC LEAKAGE AT REFERENCE TEMP 0.400 MICROAMPERES
AARG RELIABILITY INDICATOR ESTABLISHED
TEST TEST DATA DOCUMENT 81349-MIL-C-39003 SPECIFICATION
AECE ANODE TYPE SOLID
CRTP TOLERANCE RANGE PER SECTION -10.00/+10.00 PERCENT SINGLE SECTION
AEBZ SCHEMATIC DIAGRAM DESIGNATOR ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION
ADAQ BODY LENGTH 0.286 INCHES NOMINAL
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 20.0 DC SINGLE SECTION
ABJT TERMINAL LENGTH 1.500 INCHES NOMINAL
CWJK CASE MATERIAL METAL
ABHP OVERALL LENGTH (NON-CORE) 0.422 INCHES MAXIMUM
ABMK OVERALL WIDTH (NON-CORE) 0.135 INCHES NOMINAL
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
ABKW OVERALL HEIGHT (NON-CORE) 0.135 INCHES NOMINAL
AEBT TERMINAL DIAMETER 0.020 INCHES NOMINAL
AARF MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR N-3
TTQY TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
AAQL BODY STYLE W/O MTG FACILITIES, AXIAL TERMINALS
AECQ ELECTRICAL POLARIZATION POLARIZED
ABPM BODY DIAMETER 0.135 INCHES NOMINAL
CWNJ CAPACITIVE ELECTRODE MATERIAL TANTALUM
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
906D715-27 99167 A 9 5 6 ZZ
15-03-113 53643 H 1 C AF 5 TX
CS13BD225K 81349 M 9 5 3 TX
1500225 56289 A 1 C AW 3 TX
CS13BD225M 81349 M 9 5 3 TX
SNS225A020MI 12040 F 1 C 5 48
037-367 92739 R 1 C A5 5 TX
SCM225FP006A2 96214 A 1 C AF 5 TX
117002-0029 30184 F 1 C 5 48
601-0100725 42470 A 1 C AW 5 SB
TAS225K020P1A 90201 A 1 C A5 6 TX
CSR13E225K 81349 M 9 5 3 TX
CSR13E225KS 81349 M 9 5 3 TX
M39003-01-2764 81349 M 9 5 3 TU
100100 01220 F 1 C AW 6 TX
7902696-29 90536 A 1 C 5 48
15T225M20 59035 A 1 C AW 5 TX
CSR13E255K 81349 M 9 5 3 TU
150D225X0020A2 04200 A 1 C AW 5 SB
TS1-020-225-10 17554 A 1 C A5 3 TX
5060-739 05869 A 1 C AW 5 TX
TAS225M020P0A 76149 H 1 C 9 TU
35-1485 01643 A 1 C A5 5 TX
77E085P132 A1615 A 1 5 4 ZA
045-001520-276 26916 A 1 C AF 5 TX
CSR13BE225K 81349 M 9 5 3 TX
10215-0027 27914 A 1 C AW 1 TX
7890456-169 99974 F 1 C AW 5 TX
M39003/1-2763 81349 M 9 5 3 TX
SCM225FP006A2 01295 A 1 C AF 5 TX
906D715-27 83843 H 9 5 6 TX
825567-1073 65597 A 1 C AH 5 48
SCM225FR020D4 01295 A 1 C AF 5 TX
5496267P13 08771 A 1 C BB 5 TX
CSR13E225KM 81349 M 9 5 E TX
096-1007-00 12115 A 1 C 5 48
2106W21P014 97424 A 1 C AF 5 TX
150D225X9020A2B 56289 A 1 C AO 3 TX
A19908-54 07639 A 1 C 5 TX
M39003/01-3003 81349 M 2 2 3 TX
624GA00-225K 52541 H 1 C AW 6 TX
1782933-50 07187 A 1 C AF 6 TX
SNS225A020K1 26769 A 1 C AW 6 TX
150D225X9015A0 56289 A 1 C A5 5 TX
CS12BE225M 81349 M 9 5 3 TX
CSR13E225KP 81349 M 1 C AF 3 TX
184-9086-440 13499 A 9 D 5 TX
184-9086-430 95105 A 1 C AF 6 TX
CS13E225K 81349 M 9 5 3 TX
CSR13E225MM 81349 M 9 5 5 48
CS2118-27 26769 A 1 C 6 TX
CS13EE225K 81349 M 9 5 3 TX
T212A225K020SS 05397 F 1 C AF 6 TX
2503220-27 07187 A 1 C AF 5 TX
11-49012-06 53908 H 1 C 5 48
150D225X9020CD2 56752 A 1 C AW 3 TX
MILC39003-1 81349 M 1 4 3 TX
M39003-01-2283 81349 M 9 5 5 48
17706704 59661 A 1 C AF 5 TX
P15002314 56762 F 1 C AF 5 TX
6320-0013 0KDP7 A 1 C AF 5 TX
23-29908A66 94990 R 1 C AF 5 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
906D715-27 99167 HAMILTON SUNDSTRAND CORPORATION A A
15-03-113 53643 SCOPE DATA INC A H
CS13BD225K 81349 MILITARY SPECIFICATIONS A M
1500225 56289 SPRAGUE ELECTRIC CO A A
CS13BD225M 81349 MILITARY SPECIFICATIONS A M
SNS225A020MI 12040 NATIONAL SEMICONDUCTOR CORP A F
037-367 92739 AMPEX SYSTEMS CORP A R
SCM225FP006A2 96214 RAYTHEON COMPANY F A
117002-0029 30184 BUTLER NATIONAL CORP A F
601-0100725 42470 NCR CORPORATION A A
TAS225K020P1A 90201 MALLORY SONALERT PRODUCTS INC. F A
CSR13E225K 81349 MILITARY SPECIFICATIONS A M
CSR13E225KS 81349 MILITARY SPECIFICATIONS A M
M39003-01-2764 81349 MILITARY SPECIFICATIONS A M
100100 01220 SYSTRON-DONNER CORP A F
7902696-29 90536 LOCKHEED MARTIN CORPORATION A A
15T225M20 59035 COHERENT COMMUNICATOINS SYSTEMS A A
CSR13E255K 81349 MILITARY SPECIFICATIONS A M
150D225X0020A2 04200 JOANELL LABORATORIES INC A A
TS1-020-225-10 17554 AVX TANTALUM CORPORATION A A
5060-739 05869 RAYTHEON COMPANY A A
TAS225M020P0A 76149 GRACE W R AND CO A H
35-1485 01643 LEVITON MANUFACTURING CO., INC. A A
77E085P132 A1615 SELEX SISTEMI INTEGRATI SPA E A
045-001520-276 26916 NORTHROP GRUMMAN SYSTEMS CORPORA A A
CSR13BE225K 81349 MILITARY SPECIFICATIONS A M
10215-0027 27914 HONEYWELL INTERNATIONAL INC A A
7890456-169 99974 DELCO ELECTRONICS CORP A F
M39003/1-2763 81349 MILITARY SPECIFICATIONS A M
SCM225FP006A2 01295 TEXAS INSTRUMENTS INCORPORATED A A
906D715-27 83843 SUNDSTRAND CORP A H
825567-1073 65597 THALES ATM INC. A A
SCM225FR020D4 01295 TEXAS INSTRUMENTS INCORPORATED A A
5496267P13 08771 GENERAL ELECTRIC CO A A
CSR13E225KM 81349 MILITARY SPECIFICATIONS A M
096-1007-00 12115 DRS ICAS LLC A A
2106W21P014 97424 AMETEK INC. A A
150D225X9020A2B 56289 SPRAGUE ELECTRIC CO A A
A19908-54 07639 GE AVIATION SYSTEMS LLC A A
M39003/01-3003 81349 MILITARY SPECIFICATIONS A M
624GA00-225K 52541 BEEHIVE INTL A H
1782933-50 07187 HONEYWELL INTERNATIONAL INC F A
SNS225A020K1 26769 SPRAGUE PALM BEACH INC A A
150D225X9015A0 56289 SPRAGUE ELECTRIC CO A A
CS12BE225M 81349 MILITARY SPECIFICATIONS A M
CSR13E225KP 81349 MILITARY SPECIFICATIONS A M
184-9086-440 13499 ROCKWELL COLLINS INC. F A
184-9086-430 95105 ROCKWELL COLLINS INC. F A
CS13E225K 81349 MILITARY SPECIFICATIONS A M
CSR13E225MM 81349 MILITARY SPECIFICATIONS A M
CS2118-27 26769 SPRAGUE PALM BEACH INC A A
CS13EE225K 81349 MILITARY SPECIFICATIONS A M
T212A225K020SS 05397 UNION CARBIDE CORP MATERIALS SYS A F
2503220-27 07187 HONEYWELL INTERNATIONAL INC F A
11-49012-06 53908 COMPUTER AUTOMATION INC A H
150D225X9020CD2 56752 SMITHKLINE BEECHAM PHARMA INC DI A A
MILC39003-1 81349 MILITARY SPECIFICATIONS A M
M39003-01-2283 81349 MILITARY SPECIFICATIONS A M
17706704 59661 SYNTEGRA / USA/ INC A A
P15002314 56762 WESTERN PERIPHERALS INC A F
6320-0013 0KDP7 KIDDE-FENWAL INC A A
23-29908A66 94990 MOTOROLA INC. A R
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A 0 X A 1 07/06/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9N----- N Z DISCONTINUED-USE 5910-01-232-4552
DS I Z DISCONTINUED-USE 5910-01-232-4552
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P 0 X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS Y 1 EA 0 U D
DN SMS Y 1 EA 0 U 9N----- N
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 658 Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS