| CRTP |
TOLERANCE RANGE PER SECTION |
-5.00/+5.00 PERCENT SINGLE SECTION |
| ABHP |
OVERALL LENGTH |
0.470 INCHES MINIMUM AND 0.540 INCHES MAXIMUM |
| CQJJ |
NONDERATED OPERATING TEMP |
-55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
500.0 DC SINGLE SECTION |
| CWPM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT |
0.150 |
| CRHD |
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS |
-60.0/+60.0 SINGLE SECTION |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABPM |
BODY DIAMETER |
0.220 INCHES MINIMUM AND 0.290 INCHES MAXIMUM |
| CQBF |
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP |
1000.0 MEGOHMS |
| ABMK |
OVERALL WIDTH |
0.220 INCHES MINIMUM AND 0.290 INCHES MAXIMUM |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
NO COMMON OR GROUNDED ELECTRODE(S) |
| CWPK |
INSULATION RESISTANCE AT REFERENCE TEMP |
50000.0 MEGOHMS |
| ABJT |
TERMINAL LENGTH |
1.250 INCHES MINIMUM |
| CQBQ |
CAPACITANCE VALUE PER SECTION |
56.000 PICOFARADS SINGLE SECTION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 UNINSULATED WIRE LEAD |
| CQLZ |
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS |
-220.0 SINGLE SECTION |
| AAQL |
BODY STYLE |
W/O MTG FACILITIES, RADIAL TERMINALS |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.190 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
0.470 INCHES MINIMUM AND 0.540 INCHES MAXIMUM |
| ABKW |
OVERALL HEIGHT (NON-CORE) |
0.153 INCHES MAXIMUM |
| AEBT |
TERMINAL DIAMETER |
0.023 INCHES MINIMUM AND 0.027 INCHES MAXIMUM |
| CWJK |
CASE MATERIAL |
PLASTIC |
| CWQF |
QUALITY FACTOR AT REFERENCE TEMP |
1000.000 |
| CWSG |
TERMINAL SURFACE TREATMENT |
SOLDER |