5910-00-112-6916 ( 8208623 , MILC25 , CP55B4EF504V1 )

NSN Information
NSN FSC NIIN Item Name INC
5910-00-112-6916 5910 001126916 CAPACITOR,FIXED,PAPER DIELECTRIC 0000
NSN Features
MRC Parameter Characteristics
ABHP OVERALL LENGTH (NON-CORE) 2.750 INCHES NOMINAL
AAQL BODY STYLE W/MTG TABS/FLANGES TERMINAL(S) ON ONE SURFACE
TEST TEST DATA DOCUMENT 81349-MIL-C-25 SPECIFICATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED MOUNTING HOLES
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 600.0 DC ALL SECTIONS
ADAQ BODY LENGTH 2.000 INCHES NOMINAL
ABKW OVERALL HEIGHT (NON-CORE) 1.812 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.375 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 3 TAB, SOLDER LUG
BWGP SECTION QUANTITY 2
CWJK CASE MATERIAL METAL
CQBQ CAPACITANCE VALUE PER SECTION 0.500 MICROFARADS ALL SECTIONS
CRTP TOLERANCE RANGE PER SECTION -10.00/+20.00 PERCENT 1ST SECTION
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CRTP TOLERANCE RANGE PER SECTION -10.00/+20.00 PERCENT 2ND SECTION
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
CQBF INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 20.0 MEGOHM-MICROFARADS
CWPK INSULATION RESISTANCE AT REFERENCE TEMP 2000.0 MEGOHM-MICROFARADS
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 1.0000
ADAT BODY WIDTH 1.750 INCHES NOMINAL
AEBZ SCHEMATIC DIAGRAM DESIGNATOR ONE TERMINAL COMMON TO EACH SECTION
ABMK OVERALL WIDTH (NON-CORE) 1.750 INCHES NOMINAL
ADAU BODY HEIGHT 1.000 INCHES NOMINAL
CWSG TERMINAL SURFACE TREATMENT SOLDER
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
8208623 19204 A 1 C 1 TX
MILC25 81349 M 1 4 E XX
CP55B4EF504V1 81349 M 2 2 E XX
Manufacturers
Part SKU Cage Manufacturer Type Status
8208623 19204 ARMY UNITED STATES DEPARTMENT OF F A
MILC25 81349 MILITARY SPECIFICATIONS A M
CP55B4EF504V1 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 01/01/1 P 8532250080 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9B----- N
DS I
DM Z 12E2--- M V DISCONTINUED W/O REPLACEMENT
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS J 1 EA 0 U 9B----- N
DS SMS J 1 EA 0 U D
DM SMS V 1 EA 0 U Z 12E2--- M
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 723 Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS