5910-00-256-4281 ( CE53C350P , JANC62 )

NSN Information
NSN FSC NIIN Item Name INC
5910-00-256-4281 5910 002564281 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
CWSG TERMINAL SURFACE TREATMENT NICKEL
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 12.0000
ABPM BODY DIAMETER 1.500 INCHES NOMINAL
CRTP TOLERANCE RANGE PER SECTION -10.00/+50.00 PERCENT ALL SECTIONS
AECE ANODE TYPE PLAIN FOIL
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 350.0 DC ALL SECTIONS
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAQ BODY LENGTH 4.250 INCHES NOMINAL
CWJK CASE MATERIAL METAL
CQJJ NONDERATED OPERATING TEMP -40.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BWGP SECTION QUANTITY 3
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
CQBQ CAPACITANCE VALUE PER SECTION 35.000 MICROFARADS ALL SECTIONS
CWNJ CAPACITIVE ELECTRODE MATERIAL ALUMINUM
TTQY TERMINAL TYPE AND QUANTITY 4 STANDARD TUBE BASE
AECQ ELECTRICAL POLARIZATION POLARIZED
AEBZ SCHEMATIC DIAGRAM DESIGNATOR ONE TERMINAL COMMON TO EACH SECTION
AAQL BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE END
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
CE53C350P 81350 M 2 2 X XX
JANC62 81350 M 1 4 X XX
Manufacturers
Part SKU Cage Manufacturer Type Status
CE53C350P 81350 JOINT ARMY-NAVY SPECIFICATIONS A M
JANC62 81350 JOINT ARMY-NAVY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 01/01/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DM Z 1-E2--- M
DA Z Q22TEX- A N DISPOSAL
DN 9N----- N Z DISCONTINUED-USE 5910-00-949-7357
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN S9E Y 1 EA 9 U 9N----- N
DM S9E V 1 EA 9 U Z 1-E2--- M
DA S9E V 1 EA X U Z Q22TEX- A
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 TE X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC