5910-00-432-6361 ( RE350-30C1C , CL53BJ351UPG , 29F3227G37 , 29F1005G37 , 29F3227G37 , MILC3965-11 , 910218-3575 )

NSN Information
NSN FSC NIIN Item Name INC
5910-00-432-6361 5910 004326361 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
AAQL BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 50.0 DC SINGLE SECTION
CWQH DC LEAKAGE AT REFERENCE TEMP 36.000 MICROAMPERES
TTQY TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG
ADAU BODY HEIGHT 1.375 INCHES NOMINAL
AECE ANODE TYPE ETCHED FOIL
CRTP TOLERANCE RANGE PER SECTION -15.00/+75.00 PERCENT SINGLE SECTION
ADAT BODY WIDTH 0.783 INCHES NOMINAL
CQBQ CAPACITANCE VALUE PER SECTION 350.000 MICROFARADS SINGLE SECTION
AEBZ SCHEMATIC DIAGRAM DESIGNATOR ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ADAQ BODY LENGTH 1.275 INCHES NOMINAL
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 20.0000
CWJK CASE MATERIAL METAL
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
AECN IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 11.5
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
AECQ ELECTRICAL POLARIZATION POLARIZED
CWNJ CAPACITIVE ELECTRODE MATERIAL TANTALUM
CWSG TERMINAL SURFACE TREATMENT SOLDER
TEST TEST DATA DOCUMENT 81349-MIL-C-3965+11 SPECIFICATION
CQLH DC LEAKAGE AT MAXIMUM OPERATING TEMP 360.0 MILLIAMPERES
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
RE350-30C1C 05079 A 8 E 6 TX
CL53BJ351UPG 81349 M 2 2 3 TX
29F3227G37 56699 A 8 E 6 TX
29F1005G37 01002 A 8 E 5 TX
29F3227G37 01002 A 8 E 5 TX
MILC3965-11 81349 M 1 4 3 TX
910218-3575 06481 A 8 E 1 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
RE350-30C1C 05079 VISHAY SPRAGUE INC. A A
CL53BJ351UPG 81349 MILITARY SPECIFICATIONS A M
29F3227G37 56699 BC COMPONENTS A A
29F1005G37 01002 GENERAL ELECTRIC CO A A
29F3227G37 01002 GENERAL ELECTRIC CO A A
MILC3965-11 81349 MILITARY SPECIFICATIONS A M
910218-3575 06481 NORTHROP GRUMMAN GUIDANCE AND A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 05/12/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DM Z 12B2--- M 0 REVERSAL OF PHRASE CODE Z 5910-00-726-1582
DA Z Q22SLX- A
DN 9B----- N
DS N I
DF N SF9EH-V F
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS Z 1 EA 0 U 9B----- N
DA SMS Z 1 EA 0 U Z Q22SLX- A
DM SMS Z 1 EA 0 U Z 12B2--- M
DS SMS Z 1 EA 0 U D
DF SMS Z 1 EA 0 U SF9EH-V F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 SL X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS