5910-00-456-0817 ( CM06FD621J03 , MILC5-18 , 4112306-019 , 418019-35 , 815248-0005 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5910-00-456-0817 | 5910 | 004560817 | CAPACITOR,FIXED,MICA DIELECTRIC | 0000 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CRTP | TOLERANCE RANGE PER SECTION | -5.00/+5.00 PERCENT SINGLE SECTION |
| ADAU | BODY HEIGHT | 0.200 INCHES MAXIMUM |
| CQBQ | CAPACITANCE VALUE PER SECTION | 620.000 PICOFARADS SINGLE SECTION |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
| CRDN | TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | +0.0/+70.0 SINGLE SECTION |
| ADAT | BODY WIDTH | 0.510 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 0.650 INCHES MAXIMUM |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.350 INCHES NOMINAL |
| AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 10000.0 MEGOHMS |
| CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.0008 |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| CWJK | CASE MATERIAL | PLASTIC |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| CM06FD621J03 | 81349 | M | 2 | 2 | 4 | ZX | |
| MILC5-18 | 81349 | M | 1 | 4 | 4 | ZX | |
| 4112306-019 | 05869 | A | 2 | 5 | 6 | ZX | |
| 418019-35 | 96214 | A | 1 | 5 | 5 | 48 | |
| 815248-0005 | 65597 | A | 1 | 5 | 5 | 48 |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| CM06FD621J03 | 81349 | MILITARY SPECIFICATIONS | A | M |
| MILC5-18 | 81349 | MILITARY SPECIFICATIONS | A | M |
| 4112306-019 | 05869 | RAYTHEON COMPANY | A | A |
| 418019-35 | 96214 | RAYTHEON COMPANY | F | A |
| 815248-0005 | 65597 | THALES ATM INC. | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 04/30/1 | P | 8532290020 | 0000 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DM | Z | 1-E2--- | M | ||
| DN | 9N----- | N | Z | DISCONTINUED-USE 5910-01-038-5394 |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DM | S9E | V | 1 | EA | 0 | U | Z | 1-E2--- | M |
| DN | S9E | Y | 1 | EA | 0 | U | 9N----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|