5910-00-904-7504 ( CE112-6 , 00606296005714 , 36D262G050AB2B , 36D262G050AB6B )

NSN Information
NSN FSC NIIN Item Name INC
5910-00-904-7504 5910 009047504 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
AEBS CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER 0.500 INCHES NOMINAL
CRTP TOLERANCE RANGE PER SECTION -10.00/+75.00 PERCENT SINGLE SECTION
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 50.0 DC SINGLE SECTION
CWQH DC LEAKAGE AT REFERENCE TEMP 600.000 MICROAMPERES
ABJT TERMINAL LENGTH 0.250 INCHES NOMINAL
CQLH DC LEAKAGE AT MAXIMUM OPERATING TEMP 15000.0 MICROAMPERES
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED HOLE
CWSZ CASE INSULATION MATERIAL PLASTIC
AECE ANODE TYPE PLAIN FOIL
AEBZ SCHEMATIC DIAGRAM DESIGNATOR ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
ABPM BODY DIAMETER 1.453 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABHP OVERALL LENGTH (NON-CORE) 3.500 INCHES MAXIMUM
ADAQ BODY LENGTH 3.250 INCHES MAXIMUM
CWJK CASE MATERIAL METAL
CQJJ NONDERATED OPERATING TEMP -40.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CQBQ CAPACITANCE VALUE PER SECTION 2600.000 MICROFARADS SINGLE SECTION
CWNJ CAPACITIVE ELECTRODE MATERIAL ALUMINUM
ABKW OVERALL HEIGHT (NON-CORE) 1.453 INCHES MAXIMUM
AECQ ELECTRICAL POLARIZATION POLARIZED
ABMK OVERALL WIDTH (NON-CORE) 1.453 INCHES MAXIMUM
AAQL BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE END
CWQC EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS 0.20
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
CE112-6 82679 A 2 5 1 TX
00606296005714 82679 A 2 5 U ZZ
36D262G050AB2B 56289 A 2 3 3 TX
36D262G050AB6B 56289 A 9 5 5 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
CE112-6 82679 THE TECHNICAL MATERIAL CORPORATI A A
00606296005714 82679 THE TECHNICAL MATERIAL CORPORATI A A
36D262G050AB2B 56289 SPRAGUE ELECTRIC CO A A
36D262G050AB6B 56289 SPRAGUE ELECTRIC CO A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 06/22/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9N----- N Z DISCONTINUED-USE 5910-00-401-2838
DM Z 1-E2--- M
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DM S9E J 1 EA 0 U Z 1-E2--- M
DN S9E Y 1 EA 0 U 9N----- N
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 658 Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS