5910-00-930-0040 ( 557DD151U015BE , 600D157G015DD5 , 183-1277-130 )

NSN Information
NSN FSC NIIN Item Name INC
5910-00-930-0040 5910 009300040 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
AEBT TERMINAL DIAMETER 0.032 INCHES NOMINAL
CRTP TOLERANCE RANGE PER SECTION -10.00/+75.00 PERCENT SINGLE SECTION
ABPM BODY DIAMETER 0.390 INCHES NOMINAL
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 15.0 DC SINGLE SECTION
CQLH DC LEAKAGE AT MAXIMUM OPERATING TEMP 7.5 MICROAMPERES
AECE ANODE TYPE ETCHED FOIL
CWQH DC LEAKAGE AT REFERENCE TEMP 2.500 MICROAMPERES
ADAQ BODY LENGTH 1.094 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 20.0000
CWJK CASE MATERIAL METAL
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CWQC EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS 265.00
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
ABJT TERMINAL LENGTH 1.250 INCHES MINIMUM
CWNJ CAPACITIVE ELECTRODE MATERIAL ALUMINUM
TTQY TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
AAQL BODY STYLE W/O MTG FACILITIES, AXIAL TERMINALS
AECQ ELECTRICAL POLARIZATION POLARIZED
CQBQ CAPACITANCE VALUE PER SECTION 150.000 MICROFARADS SINGLE SECTION
CWSG TERMINAL SURFACE TREATMENT SOLDER
AECN IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 18.0
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
557DD151U015BE 00853 A 2 5 5 TX
600D157G015DD5 56289 A 2 5 6 TX
183-1277-130 13499 A 2 3 1 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
557DD151U015BE 00853 CORNELL-DUBILIER MARKETING INC. A A
600D157G015DD5 56289 SPRAGUE ELECTRIC CO A A
183-1277-130 13499 ROCKWELL COLLINS INC. F A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 04/15/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9N----- N Z DISCONTINUED-USE 5910-01-204-5689
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN S9E V 1 EA 0 U 9N----- N
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 723 Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS