5910-00-970-7156 ( CP72E1EK805K1 , MILC25-7 )

NSN Information
NSN FSC NIIN Item Name INC
5910-00-970-7156 5910 009707156 CAPACITOR,FIXED,PAPER DIELECTRIC 0000
NSN Features
MRC Parameter Characteristics
AAQL BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
TEST TEST DATA DOCUMENT 81349-MIL-C-25 SPECIFICATION
ADAQ BODY LENGTH 4.562 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD
ABKW OVERALL HEIGHT (NON-CORE) 8.812 INCHES MAXIMUM
CRTP TOLERANCE RANGE PER SECTION -10.00/+10.00 PERCENT SINGLE SECTION
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEBU TERMINAL HEIGHT FROM BODY 0.750 INCHES MAXIMUM
CWJK CASE MATERIAL METAL
ADAU BODY HEIGHT 7.000 INCHES NOMINAL
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
ABMK OVERALL WIDTH (NON-CORE) 3.750 INCHES NOMINAL
ABHP OVERALL LENGTH (NON-CORE) 4.562 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.813 INCHES MINIMUM AND 2.063 INCHES MAXIMUM
CQBQ CAPACITANCE VALUE PER SECTION 8.000 MICROFARADS SINGLE SECTION
CQBF INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 20.0 MEGOHM-MICROFARADS
CWPK INSULATION RESISTANCE AT REFERENCE TEMP 2000.0 MEGOHM-MICROFARADS
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 1.0000
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 2500.0 DC SINGLE SECTION
ADAT BODY WIDTH 3.750 INCHES NOMINAL
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
CP72E1EK805K1 81349 M 2 2 3 TX
MILC25-7 81349 M 1 4 3 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
CP72E1EK805K1 81349 MILITARY SPECIFICATIONS A M
MILC25-7 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 09/30/1 P 8532250080 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DA Z Q2200X- A N DISPOSAL
DN 9N----- N V DISCONTINUED W/O REPLACEMENT
DS I Z DISCONTINUED-USE 5910-01-038-1359
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS V 1 EA 0 U 9N----- N
DA SMS V 1 EA 0 U Z Q2200X- A
DS SMS Y 1 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS