5910-01-005-2612 ( 841180-1 , 841180-1 , 373332-1 , PRC-409-1 , ZD704N285 , 2V103-704A , 373332-1 , CER3A853SP )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5910-01-005-2612 | 5910 | 010052612 | CAPACITOR,FIXED,MICA DIELECTRIC | 0000 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 20000.0 MEGOHMS |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| ADAT | BODY WIDTH | 4.820 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.940 INCHES MAXIMUM |
| ABHP | OVERALL LENGTH (NON-CORE) | 11.780 INCHES NOMINAL |
| ABMK | OVERALL WIDTH (NON-CORE) | 4.820 INCHES NOMINAL |
| AAQL | BODY STYLE | W/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE |
| CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ADAQ | BODY LENGTH | 11.780 INCHES NOMINAL |
| CWJK | CASE MATERIAL | METAL |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| CQBQ | CAPACITANCE VALUE PER SECTION | 0.700 MICROFARADS SINGLE SECTION |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| ABKW | OVERALL HEIGHT (NON-CORE) | 3.940 INCHES MAXIMUM |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 10000.0 DC SINGLE SECTION |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 CONNECTOR, RECEPTACLE |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 841180-1 | 2H631 | A | 9 | 5 | 5 | TX | |
| 841180-1 | 00779 | A | 9 | 5 | 1 | KE | |
| 373332-1 | 3B150 | A | 2 | 3 | 1 | KE | |
| PRC-409-1 | 21966 | A | 2 | 5 | 5 | ZZ | |
| ZD704N285 | 13619 | A | 2 | 5 | A | ZZ | |
| 2V103-704A | 58364 | A | 2 | 5 | A | TX | |
| 373332-1 | 49956 | A | 9 | 5 | 1 | KE | |
| CER3A853SP | 23280 | A | 9 | 5 | 1 | KE |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 841180-1 | 2H631 | TYCO ELECTRONICS CORPORATION | A | A |
| 841180-1 | 00779 | TYCO ELECTRONICS CORPORATION | A | A |
| 373332-1 | 3B150 | RAYTHEON TECHNICAL SERVICES COMP | A | A |
| PRC-409-1 | 21966 | TDL INC | A | A |
| ZD704N285 | 13619 | RFI CORPORATION | A | A |
| 2V103-704A | 58364 | BYCAP INC | F | A |
| 373332-1 | 49956 | RAYTHEON COMPANY | A | A |
| CER3A853SP | 23280 | CUSTOM ELECTRONICS INC. | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | X | A | 06/22/1 | P | 8532290020 | 0000 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DF | N | SF9EH-V | F | ||
| DS | N | I | |||
| DN | 9B----- | N |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | U | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | D | 0 | EA | 0 | U | D | ||
| DF | SMS | D | 0 | EA | 0 | U | SF9EH-V | F | |
| DN | SMS | D | 0 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061400 | X | 34450 | P | 72D | Z | 9 | A | H | Z | CONDENSERS/PARTS NOI/CAPACITORS |