5910-01-052-7151 ( CP70B1DE205K , CP70B1KF205K , MILC19978-3 , 896205-6 , 10939REVC , CQ72B1GF205K3 , CP70B1FF205K1 , 3DB2-107 , MILC25 )

NSN Information
NSN FSC NIIN Item Name INC
5910-01-052-7151 5910 010527151 CAPACITOR,FIXED,PLASTIC DIELECTR 0000
NSN Features
MRC Parameter Characteristics
CWPK INSULATION RESISTANCE AT REFERENCE TEMP 1500.0 MEGOHM-MICROFARADS
AAQL BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
CWSS DIELECTRIC MATERIAL PLASTIC AND PLASTIC POLYETHYLENE TEREPHTHALATE
ADAU BODY HEIGHT 2.875 INCHES NOMINAL
CQBQ CAPACITANCE VALUE PER SECTION 2.000 MICROFARADS SINGLE SECTION
TTQY TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 600.0 DC SINGLE SECTION
ABJT TERMINAL LENGTH 0.750 INCHES MAXIMUM
ABKW OVERALL HEIGHT (NON-CORE) 3.687 INCHES MAXIMUM
ADAT BODY WIDTH 1.062 INCHES NOMINAL
CRTP TOLERANCE RANGE PER SECTION -10.00/+10.00 PERCENT SINGLE SECTION
TEST TEST DATA DOCUMENT 81349-MIL-C-19978 SPECIFICATION
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-19978/3 GOVERNMENT SPECIFICATION
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AFHW INTERNAL ELECTRICAL CONNECTION TYPE EXTENDED FOIL
ABMK OVERALL WIDTH (NON-CORE) 1.062 INCHES NOMINAL
CWJK CASE MATERIAL METAL
ABHP OVERALL LENGTH (NON-CORE) 1.812 INCHES NOMINAL
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.812 INCHES NOMINAL
ADAQ BODY LENGTH 1.812 INCHES NOMINAL
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 1.000
CQBF INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 15.0 MEGOHM-MICROFARADS
CWSG TERMINAL SURFACE TREATMENT SOLDER
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
CP70B1DE205K 81349 M 9 5 E TX
CP70B1KF205K 81349 M 9 5 E TX
MILC19978-3 81349 M 1 4 3 TX
896205-6 49671 F 1 C AF 5 TX
10939REVC 81133 A 1 C AF 5 TX
CQ72B1GF205K3 81349 M 2 2 3 TX
CP70B1FF205K1 81349 M 9 5 X XX
3DB2-107 80063 A 1 C AF 5 TX
MILC25 81349 M 9 5 X XX
Manufacturers
Part SKU Cage Manufacturer Type Status
CP70B1DE205K 81349 MILITARY SPECIFICATIONS A M
CP70B1KF205K 81349 MILITARY SPECIFICATIONS A M
MILC19978-3 81349 MILITARY SPECIFICATIONS A M
896205-6 49671 LOCKHEED MARTIN CORP A F
10939REVC 81133 NWL TRANSFORMERS A A
CQ72B1GF205K3 81349 MILITARY SPECIFICATIONS A M
CP70B1FF205K1 81349 MILITARY SPECIFICATIONS A M
3DB2-107 80063 US ARMY COMMUNICATIONS & A A
MILC25 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 12/19/1 P 8532250080 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DM Z 12B2--- M
DF N SF9EH-V F
GP ------- C
DN 9B----- N
DA Z Q2200X- A
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DA SMS Z 0 EA 0 U Z Q2200X- A
DM SMS Z 0 EA 0 U Z 12B2--- M
GP SMS Z 0 EA 0 U ------- C
DF SMS Z 0 EA 0 U SF9EH-V F
DN SMS Z 0 EA 0 U 9B----- N
DS SMS Z 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS