| CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
50.0 DC SINGLE SECTION |
| TEST |
TEST DATA DOCUMENT |
98230-0N241721-11 DRAWING |
| CQJJ |
NONDERATED OPERATING TEMP |
85.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| CWPM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT |
26.0000 |
| CWSZ |
CASE INSULATION MATERIAL |
PLASTIC |
| ABPM |
BODY DIAMETER |
0.360 INCHES MINIMUM AND 0.422 INCHES MAXIMUM |
| AARG |
RELIABILITY INDICATOR |
ESTABLISHED |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
| CWQH |
DC LEAKAGE AT REFERENCE TEMP |
2.0000 MICROAMPERES |
| AEBT |
TERMINAL DIAMETER |
0.024 INCHES MINIMUM AND 0.030 INCHES MAXIMUM |
| CRTP |
TOLERANCE RANGE PER SECTION |
-20.00/+20.00 PERCENT SINGLE SECTION |
| CQBQ |
CAPACITANCE VALUE PER SECTION |
56.000 MICROFARADS SINGLE SECTION |
| CWJK |
CASE MATERIAL |
METAL |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| ADAQ |
BODY LENGTH |
0.828 INCHES MINIMUM AND 0.890 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 UNINSULATED WIRE LEAD |
| AAQL |
BODY STYLE |
W/O MTG FACILITIES, AXIAL TERMINALS |
| AECQ |
ELECTRICAL POLARIZATION |
POLARIZED |
| AARH |
RELIABILITY FAILURE RATE LEVEL IN PERCENT |
1.0000 |
| CWNJ |
CAPACITIVE ELECTRODE MATERIAL |
TANTALUM |
| ABJT |
TERMINAL LENGTH |
2.000 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |