5910-01-068-9499 ( GKB50000 , 321117 , 1509-321117 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5910-01-068-9499 | 5910 | 010689499 | CAPACITOR,VARIABLE,CERAMIC DIELE | 0072 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CTGP | NONDERATED VOLTAGE RATING AND TYPE | 250.0 DC CONTINUOUS SINGLE SECTION |
| AECJ | QUALITY FACTOR AT 25 DEG CELSIUS | 300.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
| AFWW | TERMINAL WIDTH | 0.084 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| ABKW | OVERALL HEIGHT | 0.315 INCHES NOMINAL |
| MATT | MATERIAL | CERAMIC INCLOSURE |
| AEBC | TEMP COEFFICIENT OF CAPACITANCE IN PPM PER DEG CELSIUS | -1400.0 SINGLE SECTION |
| CTGR | ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW |
| ADAV | OVERALL DIAMETER | 0.335 INCHES NOMINAL |
| AAQL | BODY STYLE | ROTARY |
| AXGX | INSULATION DC RESISTANCE AT MAX OPERATING TEMP | 10.0 GIGOHMS |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| CTGN | CAPACITANCE RANGE IN PICOFARADS | +5.0/+50.0 SINGLE SECTION |
| AKNA | INCLOSURE TYPE | ENCASED |
| ABJT | TERMINAL LENGTH | 0.125 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| AEBD | TOLERANCE OF TEMP COEFFICIENT IN PPM PER DEG CELSIUS | -800.0/+800.0 SINGLE SECTION |
| ABHP | OVERALL LENGTH | 0.328 INCHES NOMINAL |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| GKB50000 | 52769 | A | 2 | 5 | E | TX | |
| 321117 | 89536 | A | 2 | 3 | A | TX | |
| 1509-321117 | 89536 | A | 9 | 5 | 5 | TX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| GKB50000 | 52769 | SPRAGUE-GOODMAN ELECTRONICS INC. | A | A |
| 321117 | 89536 | FLUKE CORPORATION | A | A |
| 1509-321117 | 89536 | FLUKE CORPORATION | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | X | A | 12/06/1 | P | 8532300090 | 0072 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DA | Z | Q2200X- | A | ||
| DS | N | I | |||
| DN | 9B----- | N | |||
| DF | N | SF9EH-V | F |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | U | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DA | SMS | Z | 0 | EA | 0 | U | Z | Q2200X- | A |
| DN | SMS | Z | 0 | EA | 0 | U | 9B----- | N | |
| DF | SMS | Z | 0 | EA | 0 | U | SF9EH-V | F | |
| DS | SMS | Z | 0 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| Q | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061400 | X | 34450 | P | 72D | Z | 9 | A | H | Z | CONDENSERS/PARTS NOI/CAPACITORS |