5910-01-105-8490 ( 254-101190-155 , 3111BC902U040 , 36D602G025AB2A , 360922G015AB2A , 3186BC902U040BM , 91C40RB93L , 36D922G015AB2 )

NSN Information
NSN FSC NIIN Item Name INC
5910-01-105-8490 5910 011058490 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
AEBS CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER 0.500 INCHES NOMINAL
CRTP TOLERANCE RANGE PER SECTION -10.00/+75.00 PERCENT SINGLE SECTION
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 40.0 DC SINGLE SECTION
ABKW OVERALL HEIGHT (NON-CORE) 1.391 INCHES NOMINAL
ADAQ BODY LENGTH 3.141 INCHES NOMINAL
ABJT TERMINAL LENGTH 0.281 INCHES NOMINAL
ABMK OVERALL WIDTH (NON-CORE) 1.391 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED HOLE
CWSZ CASE INSULATION MATERIAL PLASTIC
ABHP OVERALL LENGTH (NON-CORE) 3.422 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CWJK CASE MATERIAL METAL
CQJJ NONDERATED OPERATING TEMP -40.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CWNJ CAPACITIVE ELECTRODE MATERIAL ALUMINUM
ABPM BODY DIAMETER 1.391 INCHES NOMINAL
AECQ ELECTRICAL POLARIZATION POLARIZED
AEBT TERMINAL DIAMETER 0.190 INCHES NOMINAL
AAQL BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE END
CQBQ CAPACITANCE VALUE PER SECTION 9000.000 MICROFARADS SINGLE SECTION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
254-101190-155 20886 C 1 C AC 6 ZZ
3111BC902U040 99392 H 9 5 3 TX
36D602G025AB2A 56289 A 1 C AC 6 ZZ
360922G015AB2A 56289 A 1 C AC 6 ZZ
3186BC902U040BM 56699 A 9 3 E TX
91C40RB93L 99392 H 9 5 3 TX
36D922G015AB2 56289 A 1 C AC 6 ZZ
Manufacturers
Part SKU Cage Manufacturer Type Status
254-101190-155 20886 COMPRO COMPUTER SERVICES INC. A C
3111BC902U040 99392 MEPCO/ELECTRA INC ROXBORO DIV A H
36D602G025AB2A 56289 SPRAGUE ELECTRIC CO A A
360922G015AB2A 56289 SPRAGUE ELECTRIC CO A A
3186BC902U040BM 56699 BC COMPONENTS A A
91C40RB93L 99392 MEPCO/ELECTRA INC ROXBORO DIV A H
36D922G015AB2 56289 SPRAGUE ELECTRIC CO A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 01/06/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9B----- N
DS N I
DF N SF9EH-N F
DM Z 15B2--1 M 0 REVERSAL OF PHRASE CODE Z 5910-00-097-7535
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS Z 0 EA 0 U 9B----- N
DM SMS Z 0 EA 0 U Z 15B2--1 M
DF SMS Z 0 EA 0 U SF9EH-N F
DS SMS Z 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS