5910-01-107-2302 ( UY64911G , UY64911G )

NSN Information
NSN FSC NIIN Item Name INC
5910-01-107-2302 5910 011072302 CAPACITOR,FIXED,CERAMIC DIELECTR 0000
NSN Features
MRC Parameter Characteristics
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 2 RIBBON
PRMT PRECIOUS MATERIAL (NON-CORE) SILVER
CWJK CASE MATERIAL GLASS
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 0.0200
ABKW OVERALL HEIGHT (NON-CORE) 0.078 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRTP TOLERANCE RANGE PER SECTION -2.00/+2.00 PERCENT SINGLE SECTION
ABHP OVERALL LENGTH (NON-CORE) 0.250 INCHES NOMINAL
ADAT BODY WIDTH 0.250 INCHES NOMINAL
AAQL BODY STYLE W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
PMLC PRECIOUS MATERIAL AND LOCATION TERMINALS SILVER
CRHD TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -20.0/+20.0 SINGLE SECTION
ADAU BODY HEIGHT 0.078 INCHES NOMINAL
ABMK OVERALL WIDTH (NON-CORE) 0.250 INCHES NOMINAL
AEBZ SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
CWQF QUALITY FACTOR AT REFERENCE TEMP 5000.0000
ABJT TERMINAL LENGTH 0.875 INCHES MINIMUM
CWPK INSULATION RESISTANCE AT REFERENCE TEMP 1000000.0 MEGOHMS
ADAQ BODY LENGTH 0.250 INCHES NOMINAL
CQLZ TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 90.0 SINGLE SECTION
CQBF INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 100000.0 MEGOHMS
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.225 INCHES NOMINAL
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 300.0 DC SINGLE SECTION
CQBQ CAPACITANCE VALUE PER SECTION 910.000 PICOFARADS SINGLE SECTION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
UY64911G 51406 A 9 5 3 TX
UY64911G 18796 F 9 3 3 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
UY64911G 51406 MURATA ERIE NORTH AMERICA INC A A
UY64911G 18796 MURATA ERIE NORTH AMERICA INC A F
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
S X A 02/01/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DA Z Q22RCX- A
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A S P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DA SMS X 0 EA 0 U Z Q22RCX- A
DS SMS X 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 RC X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS