5910-01-119-4282 ( CL67BH080KPG , MIL-C-39006/9 , M39006-09-6501 , G320047S6 , MIL-C-39006/22 , M39006-09-8501 , MIL-C-39006/09 , 109D805X5030C2 , M39006/9-8296 , M39006-09-4501 , 415847-1 , M39006/22-0543 , T0304 , 109D805X5030F2 , CL65BH080JPE , M39006-09-6296 , M39006/09-8706 , TAP805U030P1A )

NSN Information
NSN FSC NIIN Item Name INC
5910-01-119-4282 5910 011194282 CAPACITOR,FIXED,ELECTROLYTIC 0000
NSN Features
MRC Parameter Characteristics
CRTP TOLERANCE RANGE PER SECTION -5.00/+5.00 PERCENT SINGLE SECTION
ABKW OVERALL HEIGHT (NON-CORE) 0.219 INCHES MAXIMUM
CWQH DC LEAKAGE AT REFERENCE TEMP 1.000 MICROAMPERES
TEST TEST DATA DOCUMENT 81349-MIL-C-39006 SPECIFICATION
CWPM DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 4.0000
ABMK OVERALL WIDTH (NON-CORE) 0.219 INCHES MAXIMUM
CWSZ CASE INSULATION MATERIAL PLASTIC
AARG RELIABILITY INDICATOR ESTABLISHED
AECE ANODE TYPE SOLID
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-39006/22 GOVERNMENT SPECIFICATION
AEBZ SCHEMATIC DIAGRAM DESIGNATOR ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
AARH RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.0100
CQLH DC LEAKAGE AT MAXIMUM OPERATING TEMP 2.0 MICROAMPERES
ABJT TERMINAL LENGTH 1.500 INCHES NOMINAL
CWJK CASE MATERIAL METAL
ABHP OVERALL LENGTH (NON-CORE) 0.617 INCHES MAXIMUM
CQJJ NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
TTQY TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
ADAQ BODY LENGTH 0.531 INCHES NOMINAL
CQBQ CAPACITANCE VALUE PER SECTION 8.000 MICROFARADS SINGLE SECTION
AAQL BODY STYLE W/O MTG FACILITIES, AXIAL TERMINALS
AECQ ELECTRICAL POLARIZATION POLARIZED
AECN IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 275.0
ABPM BODY DIAMETER 0.219 INCHES MAXIMUM
CWNJ CAPACITIVE ELECTRODE MATERIAL TANTALUM
CQWM NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 30.0 DC SINGLE SECTION
AARF MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR N-4
AEBT TERMINAL DIAMETER 0.025 INCHES NOMINAL
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
CL67BH080KPG 81349 M 1 C AC 6 ZZ
MIL-C-39006/9 81349 M 9 5 3 TX
M39006-09-6501 81349 M 8 E 3 TX
G320047S6 24930 A 8 E 1 ZZ
MIL-C-39006/22 81349 M 1 4 3 TX
M39006-09-8501 81349 M 1 C AC 6 ZZ
MIL-C-39006/09 81349 M 8 E 3 TX
109D805X5030C2 56289 A 8 E 5 TX
M39006/9-8296 81349 M 8 E 4 9Z
M39006-09-4501 81349 M 8 E 3 ZZ
415847-1 31550 A 8 E 1 TX
M39006/22-0543 81349 M 2 2 3 TX
T0304 26769 A 8 E 1 ZZ
109D805X5030F2 56289 A 8 E 1 ZZ
CL65BH080JPE 81349 M 9 5 E TX
M39006-09-6296 81349 M 8 E 4 9Z
M39006/09-8706 81349 M 8 E 3 TX
TAP805U030P1A 37942 A 8 E 3 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
CL67BH080KPG 81349 MILITARY SPECIFICATIONS A M
MIL-C-39006/9 81349 MILITARY SPECIFICATIONS A M
M39006-09-6501 81349 MILITARY SPECIFICATIONS A M
G320047S6 24930 ITT CORPORATION A A
MIL-C-39006/22 81349 MILITARY SPECIFICATIONS A M
M39006-09-8501 81349 MILITARY SPECIFICATIONS A M
MIL-C-39006/09 81349 MILITARY SPECIFICATIONS A M
109D805X5030C2 56289 SPRAGUE ELECTRIC CO A A
M39006/9-8296 81349 MILITARY SPECIFICATIONS A M
M39006-09-4501 81349 MILITARY SPECIFICATIONS A M
415847-1 31550 ITT CORPORATION A A
M39006/22-0543 81349 MILITARY SPECIFICATIONS A M
T0304 26769 SPRAGUE PALM BEACH INC A A
109D805X5030F2 56289 SPRAGUE ELECTRIC CO A A
CL65BH080JPE 81349 MILITARY SPECIFICATIONS A M
M39006-09-6296 81349 MILITARY SPECIFICATIONS A M
M39006/09-8706 81349 MILITARY SPECIFICATIONS A M
TAP805U030P1A 37942 YOSEMITE INVESTMENT INC A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A 0 X A 09/24/1 P 8532290040 0000
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DA Z Q2200X- A
DM Z 15B2--- M 0 REVERSAL OF PHRASE CODE Z 5910-00-230-7535
DM Z 15B2--- M 0 REVERSAL OF PHRASE CODE Z 5910-00-312-4121
DN 9B----- N
DM Z 15B2--- M 0 REVERSAL OF PHRASE CODE Z 5910-00-581-2368
DM Z 15B2--- M 0 REVERSAL OF PHRASE CODE Z 5910-00-725-7219
DS N I
GP ------- C
DF N SF9EH-V F
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P 0 X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DM SMS Z 1 EA 0 U Z 15B2--- M
DN SMS Z 1 EA 0 U 9B----- N
DA SMS Z 1 EA 0 U Z Q2200X- A
DF SMS Z 1 EA 0 U SF9EH-V F
DS SMS Z 1 EA 0 U D
GP SMS Z 1 EA 0 U ------- C
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061400 X 34450 P 72D Z 9 A H Z CONDENSERS/PARTS NOI/CAPACITORS