5910-01-151-9778 ( 328301112124 , 328301112124 , 8121-100C0G0-100K , 8121-100C0G0-100K )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5910-01-151-9778 | 5910 | 011519778 | CAPACITOR,FIXED,CERAMIC DIELECTR | 0000 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| ADAT | BODY WIDTH | 0.200 INCHES MAXIMUM |
| CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -30.0/+30.0 SINGLE SECTION |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.100 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.200 INCHES MAXIMUM |
| AEBT | TERMINAL DIAMETER | 0.016 INCHES NOMINAL |
| CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
| AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
| CQBQ | CAPACITANCE VALUE PER SECTION | 10.000 PICOFARADS SINGLE SECTION |
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 150.0 DEG CELSIUS MAXIMUM |
| CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
| ADAU | BODY HEIGHT | 0.100 INCHES MAXIMUM |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| CWJK | CASE MATERIAL | PLASTIC |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 100.0 DC SINGLE SECTION |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 328301112124 | A0810 | A | 2 | 5 | 4 | ZF | |
| 328301112124 | A3006 | R | 9 | 5 | 4 | ZF | |
| 8121-100C0G0-100K | 18796 | F | 2 | 3 | 4 | 9Z | |
| 8121-100C0G0-100K | 72982 | A | 9 | 5 | 4 | 9Z |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 328301112124 | A0810 | SELEX GALILEO SPA | E | A |
| 328301112124 | A3006 | ALENIA DIFESA SPA DIVISIONE SIST | E | R |
| 8121-100C0G0-100K | 18796 | MURATA ERIE NORTH AMERICA INC | A | F |
| 8121-100C0G0-100K | 72982 | ERIE SPECIALTY PRODUCTS INC | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | X | A | 04/25/1 | P | 8532290040 | 0000 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061400 | X | 34450 | P | P | 658 | Z | 9 | A | H | Z | CONDENSERS/PARTS NOI/CAPACITORS |